![Hatco FLAV-R-SAVOR FSHC-6W1 Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/hatco/flav-r-savor-fshc-6w1/flav-r-savor-fshc-6w1_installation-and-operating-manual_2106629013.webp)
Form No. FSHC67M-0808
11
MAINTENANCE
Figure 8. Draining Reservoir
Water Outlet
Drain Hose
GENERAL
Hatco Flav-R-Savor
®
Portable Holding Cabinets are
designed for maximum durability and performance,
with minimum maintenance.
WARNING
To avoid any injury, turn the power switch OFF,
unplug the unit from the power source and allow
to cool completely before performing any
maintenance or cleaning.
WARNING
To prevent any injury, discontinue use if power
cord is frayed or worn.
CLEANING
To preserve the bright finish of the Flav-R-Savor
Portable Holding Cabinet, it is recommended that
the exterior and interior surfaces be wiped daily with
a damp cloth. Food pans should be removed and
washed. Stubborn stains may be removed with a
good stainless steel cleaner or a non-abrasive
cleaner. Hard-to-reach areas should be cleaned
with a small brush and mild soap.
WARNING
To avoid electrical shock or personal injury, do
not steam clean or use excessive water on the
unit.
NOTICE
Use only non-abrasive cleaners. Abrasive
cleaners could scratch the finish of your unit
cabinet marring its appearance and making it
susceptible to soil accumulation.
Clean the glass door using a common glass cleaner.
NOTE: FSHC-6W & FSHC-7 series blower motor is
permanently
lubricated
and
requires
no
maintenance.
DRAINING THE RESERVOIR
WARNING
To avoid any injury, turn the power to the unit
OFF and allow to cool before draining.
It is recommended that the Flav-R-Savor water
reservoir be drained prior to moving the cabinet and
after removing lime or mineral deposits from the
water reservoir.
NOTE: The drain hose assembly is located in the
corner of the cabinet inside the door.
NOTE: Position a container to hold the water while
draining.
1. Insert the drain hose fitting into the water outlet,
located on the ceiling of the cabinet.
(See Figure 8.) Once the fitting is installed, water
will begin to drain from the hose.
2. Once the unit has finished draining, the drain
tube assembly can be removed by pressing the
release tab and gently pulling the fitting out.
3. Place the drain tube back into the holding clip
inside the door.