Form No. FSDM-0119
14
English
Symptom
Probable Cause
Corrective Action
LED lights not working.
Loose wire connection.
Verify wire connection is secure.
LED driver defective.
Contact Authorized Service Agent or Hatco for assistance.
LED light strip defective.
Replace the LED light strip. Refer to the “Replacing an LED
Light Strip” in the MAINTENANCE section.
Unit operates, but is not
circulating air inside cabinet.
Blower motor is defective.
Contact an Authorized Hatco Service Agent or Hatco for assistance.
The correct voltage may not be supplied to blower.
Unit is plugged in, but nothing
works
No power to unit.
Check electrical receptacle and verify that power supply
matches specifications on unit. If receptacle is not working,
check circuit breaker and reset, or plug unit into a different
known working receptacle.
Power cord connections are loose or disconnected.
Contact an Authorized Hatco Service Agent or Hatco for assistance.
Power cord is damaged.
Defective POWER ON/OFF (I/O) switch.
Unit is operational, but rotating
rack (if equipped) does not
turn.
Proximity switch was not relocated after door
reversal.
See “Relocating the Proximity Switch” in the INSTALLATION
section of this manual.
Proximity magnet or proximity switch not
working properly.
Contact an Authorized Hatco Service Agent or Hatco for assistance.
Incorrect voltage is supplied to rack motor.
Unit is not producing any “hot
air” inside cabinet.
Safety high-limit is tripped or open.
Contact an Authorized Hatco Service Agent or Hatco for assistance.
Incorrect voltage supplied to heating element.
Blower motor is not working.
Air heating element is defective.
Unit is heating, but is producing
too much humidity inside the
cabinet causing steam inside
unit.
Humidity control is set too high.
Adjust the humidity control to a lower setting.
Air temperature is set too low.
Adjust the temperature to a higher setting.
Humidity control is defective.
Contact an Authorized Hatco Service Agent or Hatco for assistance.
Unit is heating, but is not
producing humidity inside
cabinet. “LO H20” not flashing on
display and unit is full of water.
Incorrect voltage supplied to water heating
element or heating element is defective.
Contact an Authorized Hatco Service Agent or Hatco for assistance.
Unit is heating, but is not
producing humidity inside
cabinet. “LO H20” flashes on
display and unit is full of water.
When using distilled water, no minerals are being
sensed by low water probe.
On initial fill, add one teaspoon of salt to the water reservoir.
Low water protection system is malfunctioning. Contact an Authorized Hatco Service Agent or Hatco for assistance.
MAINTENANCE
WARNING
This unit must be serviced by trained and qualified
personnel only. Service by unqualified personnel may lead
to electric shock or burn.
WARNING
ELECTRIC SHOCK HAZARD: Turn OFF power switch,
unplug power cord, and allow unit to cool before
performing any cleaning, adjustments, or maintenance.
TROUBLESHOOTING GUIDE
Setting the De-Liming Detection Mode
When de-liming detection mode is enabled, the controller will
indicate the presence of excessive lime build-up in humidified
models by showing “DE-L” on the CABINET TEMPERATURE
display. Use the following procedure to set de-liming detection
mode “on” or “off.”
1. Press and hold either the
key or
key for four seconds.
• When de-liming detection mode is enabled, the
CABINET TEMPERATURE display shows “L-ON” for
three seconds.
• When de-liming detection mode is disabled, the
CABINET TEMPERATURE display shows “L-OF” for
three seconds.