ALL MODELS
All Decorative Heat Lamps are constructed of
aluminum and include heavy-duty mounting
hardware. Each Decorative Heat lamp features a
heat bulb contained in a vented shade provided in
powdercoated Designer or gloss colors.
DL MODELS (Standard Wattage)
Standard wattage models (DL) feature a 250 watt
bulb and include a built-in On/Off switch located at
the the stem or canopy for independent heat control.
DL units may be ordered with the optional remote
toggle (REM) switch or with no switch.
INSTALLATION
DLH MODELS (High Wattage)
High wattage models (DLH) feature a 375 watt bulb
and are available with either the remote toggle
(REM) switch or with no switch.
CAUTION
For safe and proper operation on units not
equipped with Hatco supplied switch (N-no
switch), a qualified electrician must choose an
appropriate switch for the application based on
amperage and inrush rating of the switch.
UNPACKING
1. Remove decorative lamp assembly from box
(or boxes).
2. Remove information packet. To prevent delay
in obtaining warranty coverage, fill out and
mail in warranty card.
LOCATION
WARNING
To avoid any injury or damage to the unit(s)
connect to a properly grounded electrical
supply. Contact a qualified electrician to
determine the proper voltage, wire size and
installation method.
WARNING
Decorative Heat Lamps must have a minimum of
1" (25 mm) clearance along the sides of
combustible walls and materials. If safe
distances are not maintained, discoloration or
combustion could occur.
WARNING
DL standard watt heat lamps (250 watt bulb)
must have a minimum of 16" (406 mm) above a
combustible surface or minimum clearance of 5"
(127 mm) above a non-combustible surface. If
safe distances are not maintained, discoloration
or combustion could occur.
WARNING
DLH high watt heat lamps (375 watt bulb) must
have a minimum of 27" (686 mm) above a
combustible surface or minimum clearance of 5"
(127 mm) above a non-combustible surface. If
safe distances are not maintained, discoloration
or combustion could occur.
CAUTION
For safe and proper operation, multiple
installations of Decorative Heat Lamps must
have a minimum clearance of 12" (305 mm)
between each unit.
WARNING
For safe and proper operation locate the heat
lamp at the proper height in an area that is
convenient for use.
CAUTION
Unit is not weatherproof. For safe and proper
operation locate the unit indoors
where
the ambient air temperature is constant
and is a minimum of 70°F (21°C).
CAUTION
All canopy mount units are designed to fit
a standard 4" (102 mm) octagonal junction box.
To prevent any injury or damage this junction
box must be securely anchored to the building
structure.
Min. 12 (305mm)
between other units.
NOTICE
Figure 3. Safe Mounting Distance