GENERAL

The Hatco Decorative Heat Lamps are designed 
for maximum durability and performance, 
with minimum maintenance.

CLEANING

To preserve the finish of the Decorative Heat Lamps
it is recommended that the lamp shade surface be
wiped daily with a soft damp cloth. Stubborn stains
can be removed with a mild non-abrasive cleaner.

WARNING

To avoid electrical shock or personal injury, do
not steam clean or use excessive water on the
unit.

WARNING

To avoid any injury or damage to the Decorative
Heat Lamps turn the power OFF at the
disconnect switch/circuit breaker and allow to
cool before performing any maintenance.

NOTICE

Use only non-abrasive cleaners. Abrasive
cleaners could scratch the finish of your
Decorative Heat Lamp, marring its appearance
and making it susceptible to dirt accumulation.

HEAT BULB REPLACEMENT

Each standard wattage Decorative Heat Lamp (DL)
holds one infrared heat bulb rated at 250 watts.
Each high wattage Decorative Heat Lamp (DLH)
holds one clear, uncoated infrared heat bulb rated at
375 watts. 250 watt bulbs may also be used in DLH
units.

WARNING

For safe and proper operation, do not install a
375 watt bulb into a DL standard watt lamp. 

1. To replace a bulb, place the switch in the OFF

position and allow the bulb to cool completely.

2. Bulbs have a threaded base. Unscrew the heat

bulb counter clockwise from the unit and replace
with a new bulb.

The following replacement bulbs are available from
the factory or Hatco Authorized Parts Distributor.

DL (standard wattage)
250 Watt 120V Red Coated

02.30.068.00

250 Watt 120V Clear Coated

02.30.069.00

250 Watt 120V Red Uncoated

02.30.070.00

250 Watt 120V Clear Uncoated

02.30.071.00

250 Watt 240V Clear Uncoated

02.30.083.00

DLH (high wattage)
375 Watt 120V Clear Uncoated

02.30.093.00

375 Watt 120V Red Uncoated

02.30.094.00

375 Watt 120V Clear Coated

02.30.097.00

375 Watt 120V Red Coated

02.30.098.00

WARNING

If service is required on this unit, contact your
Authorized Hatco Service Agent, or contact the
Hatco Service Department at 800-558-0607 or
414-671-6350; fax 800-690-2966, or International
fax 414-671-3976.

WARNING

This product has no “user” serviceable parts. To
avoid damage to the unit or injury to personnel,
use only Authorized Hatco Service Agents and
Genuine Hatco Replacement Parts when service
is required.

WARNING

Genuine Hatco Replacement Parts are specified 
to operate safely in the environments in which
they are used. Some aftermarket or generic
replacement parts do not have the
characteristics that will allow them to operate
safely in Hatco equipment. It is essential to use
Hatco Replacement Parts when repairing Hatco
equipment. Failure to use Hatco Replacement
Parts may subject operators of the equipment to
hazardous electrical voltage, resulting in
electrical shock or burn.

Form No. DHLM-1207

12

MAINTENANCE

Содержание DL-400

Страница 1: ...ing it to the attention of your supervisor Do not operate this equipment unless you have read and understood the contents of this manual Este manual contiene importante información sobre seguridad concerniente al mantenimiento uso y operación de este producto Cualquier falla en el seguimiento de las instrucciones contenidas en este manual puede resultar en un serio daño Si usted no puede entender ...

Страница 2: ...inspected and tested prior to shipment Important Owner Information i Introduction i Important Safety Information 1 Specifications 3 Electrical Rating Chart 3 Dimensions Shade 3 Model Designation 4 Model Descriptions 5 All Models 5 DL Models Standard Wattage 5 DLH Models High Wattage 5 Installation 5 Unpacking 5 Location 5 Assembly 6 Installing Non Track Mount 7 Installing Track Mount 8 Operation 1...

Страница 3: ...coloration or combustion could occur DLH high watt heat lamps 375 watt bulb must have a minimum of 27 686 mm above a combustible surface or minimum clearance of 5 127 mm above a non combustible surface If safe distances are not maintained discoloration or combustion could occur For safe and proper operation do not install a 375 watt bulb into a DL standard watt lamp To avoid any injury or damage t...

Страница 4: ...ection and do not use For safe and proper operation do not damage the special smooth plastic finish piece on metal ceiling plate when determining location of proper knock out holes For safe and proper operation on units not equipped with Hatco supplied switch N no switch a qualified electrician must choose an appropriate switch for the application based on amperage and inrush rating of the switch ...

Страница 5: ...DL 725 9 1 2 8 1 2 241 mm 216 mm DL 750 11 8 1 2 279 mm 216 mm DL 760 12 1 2 8 1 2 318 mm 216 mm DL 775 10 1 2 8 1 2 267 mm 216 mm DL 800 11 8 1 2 279 mm 216 mm DIMENSIONS SHADE A A A A B B B B Model DL 400 Model DL 500 Model DL 725 Model DL 750 Model DL 760 Model DL 775 Model DL 800 Model DL 700 A A A A B B B B NOTE The height dimension of the shade increases by 2 51 mm when utilizing the L lower...

Страница 6: ...Form No DHLM 1207 4 MODEL DESIGNATION TS Mount Lamp mounts with threaded stem to fixture supplied by others Threaded stem is only available as a UL recognized component UR Figure 2 Model Designations ...

Страница 7: ... the proper voltage wire size and installation method WARNING Decorative Heat Lamps must have a minimum of 1 25 mm clearance along the sides of combustible walls and materials If safe distances are not maintained discoloration or combustion could occur WARNING DL standard watt heat lamps 250 watt bulb must have a minimum of 16 406 mm above a combustible surface or minimum clearance of 5 127 mm abo...

Страница 8: ...he maximum capacity of Power Trac is 20A per circuit Check the fuses and circuits carefully before installing 20A maximum incudes all lights and appliances connected to the circuit 120 volt only maximum 1920 watts per any length track CAUTION For safe and proper operation on units not equipped with Hatco supplied switch N no switch a qualified electrician must choose an appropriate switch for the ...

Страница 9: ... to the green lead If lamp is equipped with two wires make proper ground wire connections from junction box Tuck excess wires into junction box 3 Slide the canopy cover or cord housing up until it rests against the ceiling and install the two ball cap nuts until snug to the ceiling INSTALLING NON TRACK MOUNT TS UL RECOGNIZED ONLY 1 Drill 7 16 11 mm hole through mounting fixture 2 Pass wires from D...

Страница 10: ...653 Power Trac track lighting systems only Do not attempt to use on any other track lighting system CAUTION For safe and proper operation the maximum capacity of Power Trac is 20A per circuit Check the fuses and circuits carefully before installing 20A maximum includes all lights and appliances connected to the circuit 120 volt only maximum 1920 watts per any length track The Trac system is to be ...

Страница 11: ...the dead end fitting and tighten screw IMPORTANT After Trac has been field cut make certain that each 4 1219 section or less in length has one mounting hole spaced a maximum of 6 152 mm from each Trac end section A single section of Trac that is greater than 4 1219 mm in length must have the mounting hole located a maximum of 12 305 mm from each end of the Trac with additional mounting holes locat...

Страница 12: ...itting 3 Remove cover from live end fitting Place Trac with ceiling plate attached over outlet box and mark the position of the Trac mounting holes on ceiling or wall 4 Drill mounting holes large enough for toggles and install Trac with furnished toggle bolts If Trac is to be mounted on a solid surface use 8 screws not supplied instead of toggle bolts 5 Fasten ceiling plate to outlet box with two ...

Страница 13: ...onal injury DO NOT submerge in water Do not operate if it has been submerged in water CAUTION Some exterior surfaces on the unit will get hot Use caution when touching these areas to avoid injury Place the ON OFF toggle switch in the ON position The heat bulb will light when the unit is energized Figure 9 Switches ...

Страница 14: ...heat bulb counter clockwise from the unit and replace with a new bulb The following replacement bulbs are available from the factory or Hatco Authorized Parts Distributor DL standard wattage 250 Watt 120V Red Coated 02 30 068 00 250 Watt 120V Clear Coated 02 30 069 00 250 Watt 120V Red Uncoated 02 30 070 00 250 Watt 120V Clear Uncoated 02 30 071 00 250 Watt 240V Clear Uncoated 02 30 083 00 DLH hig...

Страница 15: ...any maintenance SYMPTOM PROBABLE CAUSE CORRECTIVE ACTION Unit is not working at all Unit is turned ON but there is no light Unit not turned on Place ON OFF switch if equipped in the ON position ON OFF switch is not functioning Contact Authorized Service Agent for repair No power to unit Switch is defective Check circuit breaker and reset as necessary Contact Authorized Service Agent for repair Hea...

Страница 16: ...ons for type model Increase mounting height if too close Voltage supply too high Check power supply to unit making sure it matches rating on unit If power supply is incorrect change to match rating Switches used are not Hatco supplied Genuine Hatco components are specified to operate safely and properly in the environment in which they are used Replace switches with Genuine Hatco Parts if switches...

Страница 17: ...THER WARRANTY EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR PATENT OR OTHER INTELLECTUAL PROPERTY RIGHT INFRINGEMENT Without limiting the generality of the foregoing SUCH WARRANTIES DO NOT COVER Coated incandescent light bulbs fluorescent lights lamp warmer heat bulbs glass components Product failure in booster tank...

Страница 18: ...Form No DHLM 1207 16 NOTES ...

Страница 19: ...Form No DHLM 1207 17 NOTES ...

Страница 20: ...Kaemmerlen Parts Service St Louis 314 535 2222 NEBRASKA Anderson Electric Omaha 402 341 1414 NEVADA Burney s Commercial Las Vegas 702 736 0006 Hi Tech Commercial Service N Las Vegas 702 649 4616 NEW JERSEY Jay Hill Repair Fairfield 973 575 9145 Service Plus Flanders 973 691 6300 NEW YORK Acme American Repairs Inc Brooklyn 718 456 6544 Alpro Service Co Brooklyn 718 386 2515 Appliance Installation B...

Отзывы: