![Hatco 07.04.658.00 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/hatco/07-04-658-00/07-04-658-00_installation-and-operating-manual_2106773007.webp)
Model
Voltage
Compressor
Size
Watts
Amps
Plug
Configuration
Shipping
Weight
1 Ø
3 Ø
HCWBI-2Da
120/208
1/4 hp
3000
14.5
8.4
Hardwired
201 lbs. (91 kg)
120/240
1/4 hp
3000
12.5
7.3
Hardwired
201 lbs. (91 kg)
HCWBI-3Da
120/208
1/4 hp
3000
14.5
8.4
Hardwired
211 lbs. (96 kg)
120/240
1/4 hp
3000
12.5
7.3
Hardwired
211 lbs. (96 kg)
HCWBI-4Da
120/208
1/3 hp
4000
19.2
11.2
Hardwired
251 lbs. (114 kg)
120/240
1/3 hp
4000
16.7
9.6
Hardwired
251 lbs. (114 kg)
HCWBI-5Da
120/208
1/2 hp
6000
28.8
16.7
Hardwired
301 lbs. (137 kg)
120/240
1/2 hp
6000
25.0
14.5
Hardwired
301 lbs. (137 kg)
HCWBI-6Da
120/208
1/2 hp
6000
28.8
16.7
Hardwired
311 lbs. (141 kg)
120/240
1/2 hp
6000
25.0
14.5
Hardwired
311 lbs. (141 kg)
Form No. HCWBIm-0913
7
SPECIFICATIONS
INSTALLATION
Electrical Rating Chart
NOTE: Shipping weight includes packaging.
NOTE: The specification label is located on the back of the
control panel. See the label for the serial number and
verification of unit electrical information.
General
Hot/Cold Drop-In Wells are shipped from the factory completely
assembled and ready for use. Use the following information
and procedures to prepare the unit and installation site.
NOTE: Make sure the installation location provides enough
room for the remote mounted control enclosure,
electrical connections, and plumbing connections.
ELECTRIC SHOCK HAzARD:
• Unit must be installed by qualified, trained installers.
Installation must conform to all local electrical and
plumbing codes. Installation by unqualified personnel
will void the unit warranty and may lead to electric
shock or burn, as well as damage to unit and/or its
surroundings. Check with local plumbing and electrical
inspectors for proper procedures and codes.
• Unit is not weatherproof. Locate unit indoors.
• Remote control enclosure must be mounted on vertical
wall and installed in vertical position. Mounting remote
control enclosure in horizontal position may result in
collection of liquids and lead to electric shock.
FIRE HAzARD:
• Install unit with a minimum of 3-1/2″ (89 mm) of space
from bottom of Hydro-Heater to all combustible
surfaces to prevent combustion.
• Install unit with a minimum of 2″ (51 mm) of space
between all sides of condensing unit and any
combustible surfaces.
Locate unit at proper counter height in an area that is
convenient for use. The location should be strong enough
to support the weight of unit and contents.
WARNING
CAUTION
Transport and install unit in upright position only. Failure to
do so may result in damage to refrigeration system.
This unit is designed for use in environments where ambient
temperature is between 65°F (18°C) and 86°F (30°C).
When shipped during cold weather months, store unit for
at least 10 hours in an environment where ambient
temperature is between 65°F (18°C) and 86°F (30°C) to
prevent compressor and/or refrigerant line damage. If unit
is turned on and there is excessive noise and vibration,
turn off immediately and allow additional warmup time.
Provide louvered or grill-style openings with a minimum
size of 12" x 12"/144 square inches (31 x 31 cm/
961 square cm) in the cabinetry in front of and behind the
condensing unit for proper ventilation. Failure to provide
adequate air flow through the condensing unit may cause
unit failure and will void the unit warranty.
Do not recirculate exhaust air inside cabinet when multiple
refrigerated wells are installed together. Intake air should
enter from outside of cabinet.
Do not locate unit in an area subject to excessive
temperatures or grease from grills, fryers, etc. Excessive
temperatures could cause damage to the unit.
Damage to any countertop material caused by heat or cold
generated from Hatco equipment is not covered under the
Hatco warranty. Contact manufacturer of countertop
material for application information.
Do not obstruct access to Hydro-Heater cleanout drains.
Make sure installation location allows access to cleanout
drains for daily cleaning.
continued...
NOTICE