Symptom

Probable Cause

Corrective Action

Well not hot enough.

Unit not allowed to preheat.

Hydro-heaters  require  a  minimum  of  30  minutes  to

preheat.

Setpoint temperature set too low.

adjust the HOT controller setpoint temperature to a

higher  setting.  Refer  to  the  “Changing  the  Setpoint

Temperature” procedure in the OPERaTION section.

Digital  temperature  controller  not  working

properly.

Contact  authorized  Service  agent  or  Hatco  for

assistance.

Heating element(s) not working.

Contact  authorized  Service  agent  or  Hatco  for

assistance.

Voltage supplied is incorrect.

Verify correct voltage is supplied to unit. Unit will not

operate properly with low supply voltage.

Heated wells too hot.

Setpoint temperature set too high.

adjust the HOT controller setpoint temperature to a

lower  setting.  Refer  to  the  “Changing  the  Setpoint

Temperature” procedure in the OPERaTION section.

Digital  temperature  controller  not  working

properly.

Contact  authorized  Service  agent  or  Hatco  for

assistance.

Voltage supplied is incorrect.

Verify  correct  voltage  is  supplied  to  unit.  High  supply

voltage will cause unit to overheat and my damage unit.

No heat.

Drain lever is not in the closed position.

move drain lever forward to closed position and make

sure  Power  I/O  (on/off)  switch  is  in  HOT  “I”  (on)

position. Lever must be in the closed position for unit

to operate in HOT mode.

Circuit breaker tripped.

Reset  circuit  breaker.  If  circuit  breaker  continues  to

trip, contact authorized Service agent or Hatco.

The  Hydro-Heater  energy  cut-off  switch

was activated.

The unit overheated—likely due to a low water level.

Fill the unit to the proper water level, and move the

Power  I/O  (on/off)  switch  to  the  center  “O”  (off)

position and then back to the HOT “I” (on) position.

Temperature Control not working properly. Contact  authorized  Service  agent  or  Hatco  for

assistance.

Heating element(s) not working.

Contact  authorized  Service  agent  or  Hatco  for

assistance.

auto-Fill system not working. Water level probe is dirty and not “sensing”

properly.

Perform  the  “Daily  Cleaning”  procedure  in  the

maINTENaNCE section  with  special  focus  on  the

water level probe.

Water not supplied to fill valve.

Verify water supply is correctly installed and running.

Water fill valve malfunctioning.

Contact  authorized  Service  agent  or  Hatco  for

assistance.

Heating  element(s)  burn

out.

The well is dry or has a low level of water. Verify water supply is correctly installed and running.

If problem is not with water supply, contact authorized

Service agent or Hatco for assistance.

Deposits  built  up  in  the  heater  pipes  are

restricting water flow. (Perform the entire

“Daily 

Cleaning” 

procedure 

in

maINTENaNCE section.)

Contact  authorized  Service  agent  or  Hatco  for

assistance.

16

Form No. HCWBIm-0913

TROUBLESHOOTING GUIDE

This unit must be serviced by qualified personnel only.

Service  by  unqualified  personnel  may  lead  to  electric

shock or burn.

WARNING

ELECTRIC SHOCK HAzARD: Turn OFF power switch, turn

off power at circuit breaker, and allow unit to cool before

performing any cleaning, adjustments, or maintenance.

WARNING

HOT Mode Troubleshooting

Содержание 07.04.658.00

Страница 1: ...ualquier falla en el seguimiento de las instrucciones contenidas en este manual puede resultar en un serio lesi n o muerte Este manual contiene importante informaci n sobre seguridad concerniente al m...

Страница 2: ...Every unit is inspected and tested thoroughly prior to shipment This manual provides the installation safety and operating instructions for Hot Cold Drop In Wells Hatco recommends all installation op...

Страница 3: ...use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance Make sure food product has been heated chilled to the proper food safe temperature before placing in t...

Страница 4: ...rtop material caused by heat or cold generated from Hatco equipment is not covered under the Hatco warranty Contact manufacturer of countertop material for application information NOTICE Do not obstru...

Страница 5: ...h two digital temperature controllers and a drain status indicator light The control enclosure is connected to the condensing unit with a 4 1219 mm power cord and is connected to the Hydro Heater with...

Страница 6: ...HCWBI 4Da 58 1473 mm 27 686 mm 25 1 2 648 mm 10 254 mm Model Width A Depth B Overall Height C Well Height D HCWBI 5Da 71 1803 mm 27 686 mm 25 1 2 648 mm 10 254 mm HCWBI 6Da 84 2134 mm 27 686 mm 25 1...

Страница 7: ...e in horizontal position may result in collection of liquids and lead to electric shock FIRE HAzARD Install unit with a minimum of 3 1 2 89 mm of space from bottom of Hydro Heater to all combustible s...

Страница 8: ...e between the condensing unit and any combustible surface a minimum 3 1 2 89 mm clearance between the bottom of the Hydro Heater and any combustible surface 5 Cut two openings in the cabinetry to prov...

Страница 9: ...diagram for additional details Installing the Control Enclosure Remotely Use the following procedure to install the control enclosure remotely NOTE Standard UL approved units are equipped with a 60 18...

Страница 10: ...l of the Hydro Heater to expose the power inlet area It is located on the left rear side of the unit when facing the controls 2 Locate the terminal block inside the unit 3 Bring power leads from a pro...

Страница 11: ...d position for the unit to operate in HOT Mode 4 move the Power I O on off switch to the HOT I on position The auto Fill system will activate and the well will fill with water until the water reaches...

Страница 12: ...to operate in COLD Mode NOTICE Drain Lever in open position Drain Lever in open position 2 Install the pan support bars s into the well The number of pan support bars needed is determined by the size...

Страница 13: ...emperature The display will revert to show the current temperature of the unit Digital Temperature Controller WARNING Display Down Arrow Defrost Key Unit Active Symbol Up Arrow Standby Key SET Key Set...

Страница 14: ...on and allow the unit to cool defrost 2 Remove and wash all pans supports and adapters as well as the water baffle if installed 3 If cleaning after operating in HOT mode move the drain lever to the op...

Страница 15: ...10 Install the pipe cap s onto the clean out drain s 11 Continue with step 5 of the Daily Cleaning procedure in this section Helpful Hints for Maximum Performance in HOT Mode Keep Hydro Heater inlet a...

Страница 16: ...tact authorized Service agent or Hatco The Hydro Heater energy cut off switch was activated The unit overheated likely due to a low water level Fill the unit to the proper water level and move the Pow...

Страница 17: ...Service agent or Hatco for assistance Unit makes excessive noise and vibration when turned on Internal components have not been adequately warmed before operation Turn off unit immediately Unit should...

Страница 18: ...2 move the drain lever down to the open position allow unit to drain 3 Place the rubber stopper into the inlet strainer NOTE The inlet strainer is the strainer closest to the front of the well 4 atta...

Страница 19: ...ELLECTUaL PROPERTY RIGHT INFRINGEmENT Without limiting the generality of the foregoing SUCH WaRRaNTIES DO NOT COVER Coated incandescent light bulbs fluorescent lights heat lamp bulbs coated halogen li...

Страница 20: ...NEBRASKA anderson Electric Omaha 402 341 1414 NEVADA Burney s Commercial Las Vegas 702 736 0006 Hi Tech Commercial Service N Las Vegas 702 649 4616 NEW JERSEy Jay Hill Repair Fairfield 973 575 9145 Se...

Отзывы: