46 of 59
7. Loosen the Breather Plug and start hand pumping the oil. Keep observing the sight through glasses
which you can view the oil level on Actuator.
8. There system will hold approx. 33L of oil. When the system is full of oil there will be an
uninterrupted flow of oil. Wipe away any spills and check for oil leaks.
9. Go to the Service page and tap
Reset Count
to restart the count at zero.
Re-Assembling Drive Rod Assembly
Tools:
Gland Wrench and Spanner
Test and transport plate
Loctite 7471
Loctite 243
FML-2 Lubricant
7. Install End Cap Insert, Seal Housing, and Guide Bush into the End Cap. At this point O-rings and
seals don’t need to be installed as they are just used to home the Actuator. Gland Wrench and
Spanner.