Q-Drive Installation, Operation, and Maintenance Manual
44 of 59
Draining Oil from Actuator
1. In order to drain oil, remove ¾” BSP plug from the Oil Pump and attach a hose.
2. Place ball valves shown below in the required open or closed position
3. Locate both 1/8” hex Breather Plugs on the top of each Actuator’s End Cap and remove them.
Q-Drive Prototype (Reference Image)
12mm hose to
oil drum (on
both sides)