69
29. Technical
Data
The
Ottawa
, certifi ed in compliance with
DIN-EN 13240 : 2001 + A2 2004 and Art. 15
a B-VG (Austria),
can only be operated when the fi re box is closed; more than one device
can be connected to the chimney.
VKF-No.:
requested;
Inspection Report No. (AT):
requested
The following data applies to the chimney characteristics in accordance with EN 13384-1 / 2
Depending on the insulation of the building, the nominal thermal output of
6 kW
indicated on
20 bis 80 m²
(subject to change).
Dimensions: Height Width Depth
Stove
156 cm
48 cm
48 cm
Fire box
43 cm
28 cm
30 cm
Weight (incl. heat retaining block140kg) ceramic/soapst./steel:
324/343/319
kg
Fire Box Opening:
1106 cm²
Flue pipe diameter:
15
cm
Pipe diameter of Hase ventilation system*
10
cm
¹ Vertical chimney fl ue connector
min. 42 cm
Front view
Side view
Top view
Dimensions in cm
Combustion Values
Wood
Briquette
Nominal Thermal Output
6
6
kW
Waste Gas Mass Flow Rate
6,0
6,0
g/s
Waste Gas Outlet Temp.
280
280
˚C
Min. Supply Pressure at Nominal Thermal Output
12
12
Pa
CO content at 13% O2
971
769
mg/m³
Effi ciency
79
84
%
Particulate
19
32
mg/m³
Stove
height: 1
56
Height for
rear
installation: 1
13
Ø 48
¹ min. 4
2
Height for
top installation: 1
37
* For separate air supply in low-energy houses
and insuffi cient combustion air supply in
the room where the stove is installed.