Setpoint 1 - Operation :
This parameter is the setpoint for normal operation of every zone, it is the only one of all
parameters shown here that can also be changed by a normal operator with the user
rights „Operator“ in the detail view of this zone.
-
Setpoint 2 - Stand-By
:
This parameter is the setpoint for the stand-by operation of this zone.
Attention :
Setpoint 2 must be entered as an absolute value .
- Setpoint 3 -
Boost-temperature
:
This parameter is the setpoint for the boost-operation of this zone (boost-function for a
temporary temperature increase). The boostaddition is than added by the system to
the normal operation setpoint of this zone.
Example: Setpoint = 200°C, Boostaddition = 10°C, gives a Boost-setpoint of 210°C
The boost-setpoint is manually activated by choosing the temporary boost via the
touchscreen. Upon reaching of the boost setpoint,
temperature is held for a program-
mable time
, then automatically brought back to the normal setpoint. The boost-function
is only available during normal operation, not in stand-by operation.
De-activation of the boost is done by entering a boost-addition of „0°C“
Boost holding time
:
Value in sec.
See “Boost temperature“.