![Harvest TEC 239DM Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/harvest-tec/239dm/239dm_owners-manual_2103735007.webp)
7
Installation of Plumbing (continued)
Plumbing Diagram
Common Question
1. Is the marking dye safe for livestock consumption?
The Dye Marker uses red-colored, food-grade dye and is safe for all livestock.
2. How do I bleed the air out of the lines properly?
Remove the tips rom the check valves that the ’re threaded into and press the prime button on
the dye marker until the air is pushed out of the lines.
Troubleshooting
Problem
Possible Cause
Solution
The tips are not spraying Dye 1. The system is out of dye.
2. There is air in the lines,
preventing a steady mist
coming from the tips.
3. Damaged/pinched hose.
4. Tip is plugged.
5. Set point is set too high
1. Check the tank for solution. If the tank
is empty, refill and bleed air from lines.
2. Remove the tips from the check valves
and using the priming button bleed the
air out of the lines.
3. Inspect all the hose making sure the
lines are damaged or pinched.
4. Removed the tip from the bushing and
inspect, clean is necessary.
5. Lower the set point level at which the
user would like to have the bales
marked at.
Tank
005-9019
Pump
007-4120LF
3/8” Hose
002-9003AS
Hose Barb Tee
003-T3838
Brass Tip
004-TX-5
Drain Valve
002-2216
Figure 3