3.2.2 Single Phase Power Supply Connection (SC-1500 and SC-2000 Only)
The SC-1500 and SC-2000 must be supplied with 208-240VAC, single phase, 60 hertz electrical service. The
SC-1500 and SC-2000 feature four dedicated power terminals on the
High Voltage (TB2)
terminal block.
The illustration below shows the
Low Voltage (TB1)
and
High Voltage (TB2)
terminal blocks on the SC-
1500 and SC-2000 with the front door hidden for clarity:
•
TB2 Terminal 1 = HOT L1
•
TB2 Terminal 2 = HOT L2
•
TB2 Terminal 3 = NEUTRAL
•
TB2 Terminal 4 = GROUND
Do not over-tighten the terminal screws. Maximum tightening torque = 6 in-lbs!
NOTE
These terminals can accommodate maximum 10AWG wire.