3.4
Configuration Errors
Configuration errors occur when one or more time slots have conflicting
assignments. The following are possible configuration errors. (CH1 is the left
channel, and CH2 is the right channel).
•
CH1 TS1 = CH2 TS2 (7.5 kHz mode time slots)
•
CH1 TS1 = CH1 TS2, CH1 TS1 = CH2 TS1, CH1 TS1 = CH2 TS2,
CH1 TS2 = CH2 TS2 (15 kHz mode time slots)
•
TS1 or TS2 on either channel greater than time slot 24 (in T1 mode)
•
TS1 or TS2 on either channel = time slot 0 (in E1 mode)
•
TS1 or TS2 on either channel = time slot 16 (in E1 CAS mode)
•
PR-150C CH1 is set to 15-bit mode, but the PT-150C CH1 is not set to 15-bit
mode. (There is no detection for CH2)