10i. Turn service on by remote control, (SRVC = ON) by setting SW6, posi-
tion 8 up. You can now change the settings on the module using ISiCL
commands through the multiplexer common module.
10j. Installation is complete.
Response
Description
*OK
Valid command received
CHANNEL CARD 8, TYPE 200
Card number 8 is a PT-150C
UNDER REMOTE CONTROL
Remote control is on
SRVC = OFF
Service is off
P01 = 12 (B00001100)
Left channel, time slot 1 set to 12
P02 = 13 (B00001101)
Left channel, time slot 2 set to 13
P03 = 14 (B00001110)
Right channel, time slot 1 set to 14
P04 = 15 (B00001111)
Right channel, time slot 2 set to 15
P05 = 1 (B00000001)
15 kHz bandwidth
P06 = 0 (B00000000)
Configuration parameters