Harris Micromax FM Exciter
System Overview
REV1 01/12/2007
1-5
WARNING: Disconnect primary power prior to servicing
SCA/RDS input
2 BNC unbal
SCA/RDS input impedance
10 kOhm
SCA/RDS input level
-20 dBm
÷
+13 dBm for 2.0 kHz
continuosly adjustable
SCA/RDS amplitude/frequency response ± 0.2 dB, 40 kHz to 100 kHz
Output
RF Ouput
“BNC”-type, 50 Ohm
RF Test
BNC connector, --13 dBm +/-6 dB
50 Ohm
19 kHz pilot tone output
BNC connector, 1 Vpp
minimum load 4.7 kOhm
Composite or Mono operation
S/N
> 70dB wrt. 75 kHz, measured in the band 30 Hz
÷
20 kHz, 50 us deemph., RMS detect
Amplitude frequency response
± 0.5 dB, 20Hz
÷
15Khz
Total harmonic distortion (THD)
< 0.08%
MPX operation
composite S/N
> 70 dB wrt. 75 kHz, measured in the band 30 Hz
÷
20 kHz, 50 us deemph., RMS detect
MPX amplitude frequency response
± 0.3 dB, 30 Hz
÷
53 KHz
± 0.3 dB, 53 KHz
÷
100 KHz
MPX total harmonic distortion (THD)
< 0.08 %
Stereo separation
> 55 dB (typ. 60dB, with external stereo generator)
Stereo operation
S/N FM Stereo
> 70 dB wrt. 75 kHz, measured on decoded
channels, in the band 30 Hz
÷
20 KHz,
50 us deemph, RMS detector
Audio frequency response
± 0.5 dB, 30 Hz
÷
15 KHz
Total harmonic distortion (THD)
≤
0.08 %
Stereo separation
> 50 dB
Connections
Interlock connector
BNC, inhibits RF power output when shorted to
ground
Service (serial) interface
DB9 female RS232
Remote
DB15 female
TABLE 1-1 (continued)
Technical Specifications
Содержание Micromax
Страница 1: ...Micromax 30 Watt Solid State FM Exciter Operation Manual ...
Страница 2: ...WARNING Disconnect primary power prior to servicing HarrisMicromaxFMExciter REV 1 01 12 2007 ...
Страница 6: ...WARNING Disconnect primary power prior to servicing HarrisMicromaxFMExciter REV 1 01 12 2007 ...
Страница 8: ...WARNING Disconnect primary power prior to servicing HarrisMicromaxFMExciter REV 1 01 12 2007 ...
Страница 30: ...3 8 WARNING Disconnect primary power prior to servicing HarrisMicromaxFMExciter Operation REV1 01 12 2007 ...