3-4
WARNING: Disconnect primary power prior to servicing
Harris Micromax FM Exciter
Operation
REV1 01/12/2007
Press the KNOB to enter frequency setup. Three arrows will appear to the left of the frequency
display as shown below. Then use the knob to change the operating frequency. When the desired frequency
is displayed on the screen, press the knob to change to the new frequency.
3.5
Adjusting modulation deviation level
Modulation level adjustments are on the rear panel next to each audio input. Adjust modulation
deviation levels using a small screwdriver as shown below. On front panel, 100% modulation is indicated
when the bar graph on the default menu is equal to the 5 vertical dots on display as shown below.
MPX (composite) level adjust
Mono or left channel level adjust
Right channel level adjust
(REAR PANEL VIEW)