NetWave DirectView Broadcast Console Operations & Technical Manual
Revision A
5 – NetWave Servicing
Harris Broadcast
5-8
PR&E
Table 5-5. 90-1858-1 DC Cable Color Codes and Pin-outs
Supply
End
Signal
Wire Color
Console
End
1
+48 V
Red
1
2
+48 V
White
4
3
Shield
Clear Cover
2
4
+48 V Return
Return Black
6
5
+48 V Return
Return Green
3
-
-
No connection
5
Figure 5-4. DC Power Cable Connectors
Product Description
Use this discussion with Figure 5-5 for details on NetWave console main component locations and functions.
The +48 volts from a 99-1205 or a 99-1206 power supply plugs into J21 on the 99-1421 Monitor & Output
card. When a redundant supply is used, a 90-1995 Redundant Coupler couples the two power supplies into
the NetWave console through a pair of low-voltage drop Schottky diodes.
Figure 5-5. NetWave Console Main Components
99-1205 Supply End
Console End