E. Electrical connections + motor
Important remark: all electrical connections have to be made by a qualified fitter/electrician (see guar-
antee card 2.1.). Electrical fitting- and connection diagrams have to be applied in a correct way. The
electrical accessories used have to be conform the norms and/or demands in vigor.
E.1. Connection diagram of the single-pole switch
Four wires exit the motor: yellow-green (earth), blue (neutral), brown and black (up and down direc-
tion). Three wires exit the fuse box: yellow-green (earth), blue (neutral) and a phase wire. The phase
wire exiting the fuse box is to be connected to clamp L. If necessary, reverse the brown and black wire
of the motor within the switch, so that the arrows on the switch correspond to the raising and lower-
ing direction of the awning.
Connect the two blue wires in the housing of the switch by means of a cable. Do the same for the two
earth wires.
yellow / green
brown / black
brown / black
red
blue