Error codes and corresponding chlorinator solutions
Code
Reason for failure Remark
Solution
E1
Coal fin
temperature is too
high
Coal fin temperature is
too high
First check if the error code E6 is present, if
present , check if the temperature sensor is
connected , if connected replace the sensor ;
E2
The water
temperature is
below the normal
range
The fault must be
corrected manually
If error code E6 is not present, check the
installation
E3
No water
The normal
temperature range is
between 10-45 degrees
Celsius
First check if error code E7 is present, if this is
the case, check if the temperature sensor is
confirmed. if this is the case, replace the sensor;
E4
The salt
concentration is
too high
Under normal use,
enough water in the
chlorine supply is
required.
If the E7 error code is not present. check if the
water is within the operating temperature
range
E5
The salt
concentration is
too low
Normal salt
concentration is 3500
ppm
First check that the water level detector is
attached. Check if there is water leaking or if
there is air present. If water is present, wash
the water level detector.