7
5
Make the electrical connections in such a way that:
-
The salt electrolysis and acid pump cannot work if the filter pump does not work.
-
The salt electrolysis and acid pump can be switched off if the filter pump is working.
6
Connect the pH and redox measuring heads to the BNC connection to the positions
provided for this purpose:
pH (left)
RX (right)
7
Start filterpomp.
8
Verify that the installation does not leak.
9
Stop the filter pump. Remove the elektrodes from the holder and kalibreer pH and redox
electrodes..
Attention!!
(1)
If you do not have a bypass configuration, insert two rubber caps (product code:
ZFPX4640) into the electrode bases to prevent water from spraying out of the
electrode bases during calibration.
(2)
The electrode calibration procedure may take several minutes. To ensure an
accurate reading, it is important to follow the steps below.
(3)
If you do not have a bypass configuration, insert two rubber caps (product code:
ZFPX4640) into the electrode bases to prevent water from spraying from the
electrode bases during calibration.
(4)
The electrode calibration procedure may take several minutes. To ensure an
accurate reading, it is important to follow the steps below.
(5)
Make sure that the calibration fluids used in the calibration process always match
the values indicated and that the fluids are not contaminated.
Zoutelectrolyse
filter pump
safety fuse with timer