Technical Specifications
PWRLink II 4800T Optical Transmitter Product Manual Rev A (2/02)
A–3
A.4 User
Interface
Front panel
Bi-state status LED: Normal = Green, Alarm = Red
Module selection indicator: Yellow LED
RF attenuation adjustment
Monitor point:
Monitor port to RF input: -20 dB
Flatness: ±1.0 dB
Return loss: >16 dB
Connector type: Female F
Rear panel
RF input connector type: Female F
Optical output (for connector types available, see Section A.8)
Element Management System—NETWatch Site Controller
Interface: RS-485, RS-232C connectors (in HLP 4200)
Carrier: Externally generated
A.5 Power
Requirements
Nominal: +24 VDC; supplied by HLP 4200 bus
Maximum: +28 VDC
Consumption: 22 Watts maximum
A.6 Environmental
Operating temperature
1
: 0
˚
to +50
˚
C (+32
˚
to +122
˚
F)
Storage temperature: -40
˚
to +70
˚
C (-40
˚
to +158
˚
F)
Automatic fan adjustment at: 40
˚
& 50
˚
C (104
˚
& 122
˚
F)
Relative humidity: 85% non-condensing
Over temperature laser protection: Software and hardware
1.
For operation over entire temperature range, subtract 2 dB from CSO and CTB worst-case
performance specifications.