48 Alarms for the NSG Unit
CHAPTER 3
Web client
:
QAM X Symc loss
Control panel
:
Loss of Sync
QAM modulator cannot
lock on its input. This
type of alarm may
indicate a QAM
modulator hardware
configuration failure.
Reapply the QAM
configuration:
■
Set the output QAM type
to a new value. Check
for alarm clearance.
■
Return to the original
output QAM type.
Web client
:
TSout X Overflow
Control panel
:
OverFlow
The actual output bit
rate exceeds the
configured QAM output
bit rate.
Deprovision several services
of the specific output until
the alarm clears.
Web client
:
Upconverter X
General alarm
Control panel
:
General alarm
An upconverter internal
hardware failure.
Restart the NSG:
■
Turn it off by
disconnecting the power
cord.
■
Turn it back on and
check for alarm
clearance.
Web client
:
Upconverter X
Power failure
Control panel
:
Power failure
Power level to the
upconverter
momentarily exceeded
limits. Alarm clears
when you restart the
NSG.
Restart the NSG:
■
Turn it off by
disconnecting the power
cord.
■
Turn it back on and
check for alarm
clearance.
Web client
:
Upconverter X
Communication
failure
Control panel
:
Comm failure
Indicates a hardware
failure.
Call Customer Support.
Web client
:
Upconverter X RF
level out of range
Control panel
:
RF range
This type of alarm is
generated when the RF
output power level falls
below limit.
Call Customer Support.
Alarm Message
Description
Solution
Содержание NSG 9108
Страница 6: ...vi Table of Contents...
Страница 26: ...18 Back Panel CHAPTER 1...
Страница 60: ...52 APPENDIX A...
Страница 71: ...63 Advanced Fiber Optic Connections Cascading with IP Switching...
Страница 73: ...65 Advanced Fiber Optic Connections Connecting a DWDM...
Страница 74: ...66 Connecting a DWDM APPENDIX C...
Страница 76: ...68 Contacting Harmonic for Technical Support APPENDIX D...
Страница 80: ...VAM Glossary 72...