43
Troubleshooting
Warnings for the NSG Unit
Web client
:
NSG Cooling fan X
failure (X=1-4)
Control panel
:
Fans-X failure
Fan X (X = 1-4) is
malfunctioning.
1.
Check fan's power
connector.
2.
Replace fan. You can
replace the fan while the
system is on, as follows:
■
Disconnect the fan
power cable. Release
the fan's four screws.
■
Replace with a new fan.
Web client
:
NSG Firmware file
download failed.
Control panel
:
FW download
Failed to download new
firmware file using the
specified
upgrade_server/path/
filename.
Check to see if the path is
correct.
Web client
:
NSG Incomplete or
corrupt firmware file.
Load failed, booting
with previous
firmware.
Control panel
:
FW corrupt file.
Firmware download
from upgrade server
succeeded, but new
firmware could not be
loaded to Flash due to
file corruption.
Call Customer Support.
Web client
:
TSout nearing
oversubscription.
Control panel
:
Nearing Oversub
The QAM utilization is
above the configured
threshold.
Consider using another
QAM.
Web client
:
TSout X Number of
services exceeds
limit
Control panel
:
No srvcs exceed
The number of
provisioned services
exceeds the configured
threshold per TSout.
■
Deprovision one or
more services.
Or
■
Configure a higher
threshold
Warning Message
Description
Solution
Содержание NSG 9108
Страница 6: ...vi Table of Contents...
Страница 26: ...18 Back Panel CHAPTER 1...
Страница 60: ...52 APPENDIX A...
Страница 71: ...63 Advanced Fiber Optic Connections Cascading with IP Switching...
Страница 73: ...65 Advanced Fiber Optic Connections Connecting a DWDM...
Страница 74: ...66 Connecting a DWDM APPENDIX C...
Страница 76: ...68 Contacting Harmonic for Technical Support APPENDIX D...
Страница 80: ...VAM Glossary 72...