XXV Pellet Stove
installing
Place the stove on a non-combustible floor
protector that extends a minimum of 6 inches to
the front (15cm), 6 inches to the sides (15cm)
and 6"(15cm) to the rear, which is flush with the
rear of the hopper. Front and side floor protection
measurements are made from the firebox or
window opening. Floor protection must also be
positioned under horizontal flue pipe, extending
2" (51mm) beyond each side of the pipe. The
minimum floor protector material is 20 gauge
sheet metal. Other floor protector materials are
ceramic tile, stone, brick, etc.
Place the stove away from combustible walls at
least as far as shown in Figures 2 and 3.
Note that the clearances shown are minimum for safety but do
not leave much room for access when cleaning or servicing.
Please take this into account when placing the stove.
Connect the power cord to a 120 V.A.C. 60Hz grounded
receptacle. (A surge protector is recommended to protect the
circuit board.) Also be sure that the polarity of the outlet that
the stove is plugged into is correct.
Prior to installing the flue pipe, connect a draft meter. Turn the
Feed Adjuster dial to "Test". Record the first reading. Connect
flue pipe to stove and be sure all doors and windows in the
home are closed. Record the second draft reading_______.
If the second reading is more than .05" lower than the first
reading, check for possible restrictions or the need for outside
air (see page 10). For more information on the draft test
procedure, refer to Page 17.
4"/10cm
from back of
top flue vent
to wall
18"/
46cm
Fig. 5: Optional Top Vent Pipe Clearances
Fig. 2
6.25"
16cm
6.25"
16cm
installation
6"/15cm
from
pipe to wall
dO nOt inStall in a SleePing rOOM.
warning
cautiOn
the Structural integritY OF the
ManuFactured hOMe FlOOr, wall, and ceiling/
rOOF MuSt be Maintained.
Mobile home installation
When installing this unit in a mobile home several requirements
must be followed (Reference HUD Regulation #24CFR3280):
1. The unit must be bolted to the floor. This can be done by
using clips (part # 2-00-677110B) and 1/4" lag screws.
2. The unit must be connected to outside air. See page 10.
3. Floor protection and clearances must be followed as shown
above.
4. Unit must be grounded to the metal frame of the mobile
home.
5. Chimney must meet requirements of CAN/ULC-S629,
Standard for 650°C Factory Built Chimneys. Follow
Manufacturer's guidelines concerning height and clearances
to combustibles. Use the same manufacturer's components
to provide an effective vapor barrier where the chimney or
other component penetrates to the the exterior of the mobile
home.
dO nOt MiX cOMPOnentS FrOM diFFerent
ManuFacturerS.
The top section of chimney and the
chimney cap must be removable to a maximum height of 13.5'
for transport of the mobile home.
cautiOn: this appliance must be vented to the outside.
Floor Protector minimum: 32" X 32"
(813mm X 813mm)
Fig. 4
0"/0cm
32" minimum
32" minimum
6"
(15cm)
6"/15cm
from glass
*Measure front and side floor protection from the glass opening.
Fig. 3
12"/ 31cm
3"/ 8cm