17
Soundcraft ViSi Remote User Guide 0614
PROCESSING PAGES — MISC (Si only)
The illustration below is of an Si Performer 2.
Input Level
Post processing level
HPF engage
switch
HP filter
parameter
Input Gain/Trim
control.
48v/Phantom power
switch
Phase reverse
switch
Stereo indicator
(Si Performer only)
Mono Assign
switch
Channel Isolate indicator
Time Delay
parameter
Pan
parameter
LR Assign
switch
Meter displays:
ViSi Remote provides two meter points that can provide a useful channel overview. The
first meter point is at the input (the same as the console). This is located on the left and
should be used with the gain control in order to achieve the optimum level.
The second meter located to the right of the screen provides a post-processing level
that can be used to observe the effect of the ACS on the channel. Clipping on this fader
would indicate that a processor is adding too much gain onto the channel (too much
broadband boost on an EQ/Surplus makeup gain on a compressor).
Note: Although clipping the Post-processing meter would not result in audible
clipping (thanks to 40-bit floating point DSP), it is best to keep this signal under
control to achieve the best gain structure for mixing.