6.5.2
6.5.2: INPUT CHANNEL > INPUT
®
Vi3000 USER MANUAL
6.5.2: INPUT CHANNEL > INPUT
Frequency Con-
trol
Field / Group: FREQ
Range Low
Range High
Adjust the centre
frequency (band pass)
or cut-off frequency
(shelving) of the EQ.
All changes are reflected in the graphic Vistonics touch
screen EQ section. Any band currently being adjusted
is shown highlighted in white. All four bands feature full-
range frequncy control.
20Hz
20kHz
EQ Bandwidth /
Q Control
Field / Group: BwOct
Range Low
Range High
Adjust the bandwidth
or Q (inverse) of the
current filter.
You can chose whether the adjustment unit is Bandwidth
or Q via the main settings screen by hitting the [menu]
button.
0.3Q/0.2oct
8.7Q/4oct
Shelf Select
Field / Group:
BwOct/Q
Inactive
Active
Choose a shelving
response for the filter.
The shelf response is available to the high (HF) and low
(LF) EQ bands.
Bell
Shelf
Gain Control
Field / Group: GAIN
Range Low
Range High
Adjust the gain applied
to the defined filter
band.
-18dB
+18dB
EQ Band In
Field / Group: GAIN
Inactive
Active
Switch the selected EQ
band into the Equaliser
signal path.
Please note, there is also an EQUALISER IN button to
switch the equaliser section into the channel signal path.
Out
In
Flatten All
Field / Group:
Active
Flatten settings for the
whole equaliser section.
Flatten
EQ In
Field / Group: EQUAL-
ISER
Inactive
Active
Switch the whole equal
-
iser section into and out
of the channel signal
path.
Respects in/out settings on individual bands. When the
Equaliser section is 'In' the EQ graphic on the Vistonics
input channel touch screen area will be highlighted in
red.
Out
In
Содержание SoundCraft Vi3000
Страница 1: ...User Guide v1 4...
Страница 14: ...Vi3000 USER MANUAL 3 0 3 3 0 QUICK START 3 0 QUICK START Inputs Controls Input Channel Access...
Страница 16: ...Vi3000 USER MANUAL 3 0 5 3 0 QUICK START 3 0 QUICK START Outputs Control...
Страница 18: ...Vi3000 USER MANUAL 3 0 7 3 0 QUICK START 3 0 QUICK START Copy Paste Move LIbrary...
Страница 20: ...Vi3000 USER MANUAL 3 0 9 3 0 QUICK START 3 0 QUICK START Main Menu System Lexicon FX...
Страница 26: ...5 0 5 0 Operations Overview Vi3000 USER MANUAL 5 0 Operations Overview 5 0 Operations Overview...
Страница 68: ...Vi3000 USER MANUAL 7 0 7 0 OUTPUTS 7 0 OUTPUTS Outputs Auxilliaries Groups and LCR Mix busses...
Страница 172: ...4 3 INPUT CHANNEL DYNAMICS Vi3000 USER MANUAL 4 3 INPUT CHANNEL De Esser Vi3000 USER MANUAL 17 0 17 0 FX 17 0 FX...