Control panel menus
23
FACTORY
DEFAULT
LOAD
ARE YOU SURE?
NO
Return all settings (except calibrations) to
factory defaults
YES
INFORMATION
POWER ON TIME
TOTAL
0 - xxx HR
Display number of hours fixture has been
powered on since manufacture (not
user-resettable)
RESETTABLE
CLEAR
COUNTER?
YES/
NO
Display number of hours fixture has been
powered on since counter was last reset
(user-resettable)
LAMP ON TIME
TOTAL
0 - xxx HR
Display number of hours lamp has been
powered on since manufacture (not
user-resettable)
RESETTABLE
CLEAR
COUNTER?
YES/
NO
Display number of hours lamp has been
powered on since counter was last reset
(user-resettable)
LAMP STRIKES
TOTAL
0 - xxx
Display number of lamp strikes since
manufacture (not user-resettable)
RESETTABLE
CLEAR
COUNTER?
YES/
NO
Display number of lamp strikes since
counter was last reset (user-resettable)
SW VERSION
V.X.X.X
Display currently active fixture software
(firmware) version
RDM UID
4D50.XXXXXXXX
Display fixture’s unique RDM ID
FANS
BASE FAN 1
...
HEAD FAN 12
xx.x V
Display current voltage of all cooling fans:
base fans 1 - 3, lamp fan and head fans 1 -
12.
HUMIDITY
HEAD
xx%
Display relative humidity in head
BASE
xx%
Display relative humidity in base
TEMPERATURE
MAIN PCB
...
BASE
x.x °C
Scroll through current readings on all PCB
temperature sensors: main PCB, pan/tilt
PCB, CMY PCB, effects PCB, zoom/focus
PCB, fan PCB 1, fan PCB 2, head PCB,
base PCB
DMX LIVE
RATE
0 - 45
xx Hz
DMX transmission speed in packets per
second
QUALITY
0 - 100
xx %
Percentage of packets received
STROBE
...
FUNCTION
0 - 255
Scroll through DMX channels in sequence
to see DMX values currently being
received on each channel
FIXTURE TEST
TEST ALL
Run test sequence of all functions.
Press MENU button to exit test.
TEST EFFECTS
STROBE
...
FOCUS
Run test sequence of individual effects.
To test a specific effect, use UP/DOWN
buttons to scroll to effect. Press ENTER to
pause and restart test sequence.
Press MENU button to exit test
TEST PAN/TILT
PAN
Run test sequence of pan functions.
Press MENU button to exit test.
TILT
Run test sequence of tilt functions.
Press MENU button to exit test.
MANUAL
CONTROL
RESET
HEAD MOTORS
Reset head motors only
PAN / TILT MOTORS
Reset pan and tilt motors only
ALL MOTORS
Reset all motors
LAMP ON/OFF
ON
Strike lamp
OFF
Douse lamp
STROBE
...
PAN/TILT SPEED
0-255
Scroll through effects, then manually
control an effect
Menu level 1
Menu level 2
Menu level 3
Menu level 4
Notes