![Harman Martin ERA 500 Hybrid IP Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/harman/martin-era-500-hybrid-ip/martin-era-500-hybrid-ip_user-manual_3979110016.webp)
16
ERA 500 Hybrid IP User Guide
To run a test:
• In the
FIXTURE TEST
menu, scroll to
TEST ALL
,
TEST EFFECTS
or
TEST PAN/TILT
and press
ENTER.
• In the
TEST EFFECTS
menu, scroll to the effect you want to test and press ENTER to start a test
sequence for that effect.
• In the
TEST PAN/TILT
menu, choose
PAN
or
TILT
, make sure that there is no danger of the head
colliding, then press ENTER to start the test sequence.
• Press MENU to stop the test sequence.
Manual control
The
MANUAL CONTROL
menu lets you reset the ERA 500 Hybrid IP, power the lamp on and off, and
operate the fixture’s effects without a DMX controller.
To manually control effects in the
MANUAL CONTROL
menu, select the effect that you want to control, then
enter a value from 0 to 255 to apply a command. The menu items and values correspond to the commands
listed in the DMX protocol in this User Manual.
When you exit the
MANUAL CONTROL
menu, the fixture will keep its effect positions and settings until you
enter a new menu. When you do this, the fixture will revert to default positions and settings. The fixture will
also revert to default positions and settings if you exit and then re-enter
MANUAL CONTROL
.
Service utilities
The
SERVICE
menu provides utilities for technicians rigging or servicing the fixture:
•
ERROR LIST
displays a complete list of any errors that the fixture has detected and any warnings that the
fixture has stored in memory.
•
PAN/TILT FEEDBACK
lets you disable feedback to the fixture software from the pan, tilt and effects
positioning systems. If feedback is set to
ON
(the default setting) and a pan, tilt or effect position error is
detected, the shutter closes and the effect resets. This feature can be disabled by setting feedback to
OFF
.
The
OFF
setting is not saved when the fixture is powered off, and the system will be re-enabled the next
time the fixture starts. If a pan/tilt position error occurs and the system cannot correct pan/tilt position
within 10 seconds, feedback is automatically disabled.
•
CALIBRATION
lets you set home positions of pan, tilt and all the fixture’s mechanical effects if the fixture
loses adjustment. See ”Calibration” below for more details. Adjustment may also be required by some
firmware updates. If so, this will be mentioned in the firmware release notes.
•
LOAD DEFAULTS
returns the fixture to its factory default home positions (or to the home positions saved
using the
SAVE SETTING
command if any home positions have been saved there).
•
SAVE SETTING
replaces the fixture’s factory default home positions with the home positions currently set
in the
CALIBRATION
menu.
Caution!
The SAVE SETTING command makes permanent changes! See ”Calibration” below for more
details.
•
DEHUMIDIFY
runs a process which removes humidity from inside the fixture. Among other things, the
process requires the removal of the fixture’s pressure relief valves. See the ERA 500 Hybrid IP Safety and
Installation Manual (supplied with the fixture and available for download at www.martin.com) for
instructions on carrying out dehumidification.
Calibration
Martin fixtures are adjusted and calibrated at the factory to ensure uniform behavior in different fixtures.
Further calibration should only be necessary if fixtures have been subjected to abnormal shocks during
transport or if normal wear and tear has affected alignment after an extended period of use. You can also
use calibration to fine-tune fixtures for a particular location or application.
The
SERVICE
→
CALIBRATION
menu lets you define offsets in the fixture software to adjust the positions
of pan, tilt and effects.