Страница 3: ...8 Zoom and focus 8 Pan and tilt 8 Control panel 9 Control options 11 DMX 11 RDM 11 Fixture setup 14 Personality 14 Factory defaults 15 Fixture information readouts 15 DMX signal monitoring 15 Test se...

Страница 4: ...apply power to the fixture apply power to the power input cable The fixture s Neutrik powerCON TRUE1 connectors can also be connected live or under load Lamp lifetimes The ERA 500 Hybrid IP in combina...

Страница 5: ...oarse channel Shutter and strobe effects The ERA 500 Hybrid IP s mechanical shutter provides instant blackout and snap open as well as pulse effects and regular or random strobe effects Dimming Smooth...

Страница 6: ...you set the indexed angle or the rotation direction and speed of the gobo that is selected on channel 8 The standard gobos are shown in the correct order in Figure 2 All gobos are interchangeable and...

Страница 7: ...n and control type indexing gobo wheel shake and continuous gobo wheel scrolling The gobos on the static gobo wheel are shown in the correct order in Figure 3 Figure 3 Static gobo wheel 1 Gobo 1 Iris...

Страница 8: ...effects for maximum punch but will give more even projections when using the fixture as a spot projector Frost Applying the Frost effect softens the beam The heavy frost filter is located in front of...

Страница 9: ...a red warning triangle on the right below the DMX address Press the ENTER button to see the messages Display appearance The display flashes if no DMX signal is being received The display can be set to...

Страница 10: ...panel A SERV message appears in the display Pan and tilt remain frozen until the next power off power on cycle Important You must use the MENU ENTER key combination immediately after applying power Pu...

Страница 11: ...Device Management in accordance with ESTA s American National Standard E1 20 2006 RDM is a bi directional communications protocol for use in DMX512 control systems it is the open standard for DMX512...

Страница 12: ...PORTED_PARAMETERS PARAMETER_DESCRIPTION Product information DEVICE_INFO DEVICE_MODEL_DESCRIPTION MANUFACTURER_LABEL DEVICE_LABEL SOFTWARE_VERSION_LABEL BOOT_SOFTWARE_VERSION_ID DMX Setup DMX_PERSONALI...

Страница 13: ...options 13 Manufacturer specific RDM Parameter IDs GET allowed SET allowed RDM parameter ID s slot 21 22 Notes Fixture behavior LAST_STATE 0XA004 Sets behavior if loss of DMX signal Set to 00 BLACKOUT...

Страница 14: ...ooling fan operation for the lowest possible temperature by setting cooling fans to run constantly at full speed DMX RESET lets you decide whether it should be possible to reset the fixture via DMX wi...

Страница 15: ...press ENTER to display the current voltage at the fan s input terminals HUMIDITY displays humidity level readouts as percentage relative humidity for the base and the head Excessive humidity can resu...

Страница 16: ...be disabled by setting feedback to OFF The OFF setting is not saved when the fixture is powered off and the system will be re enabled the next time the fixture starts If a pan tilt position error occ...

Страница 17: ...ant Do not switch the fixture off or disconnect the source of the firmware during an update or the firmware will be corrupted If you update firmware to a newer version check the ERA 500 Hybrid IP area...

Страница 18: ...avoid changes in pan and tilt position or changes in effects being visible to the audience or spectators you can set the fixture to black out close the shutter during any of the following Pan and or...

Страница 19: ...56 57 63 64 65 66 71 72 73 78 79 80 85 86 87 92 93 94 99 100 101 106 107 108 113 114 115 120 121 122 127 128 190 191 192 193 255 Color wheel Indexing Solid colors Open Color 1 Red Color 2 Aquamarine...

Страница 20: ...o rotation CCW slow fast Snap 0 10 0 4 5 9 10 14 15 19 20 24 25 29 30 34 35 39 40 44 45 49 50 54 55 59 60 79 80 84 85 89 90 94 95 99 100 104 105 109 110 114 115 119 120 124 125 129 130 134 135 184 185...

Страница 21: ...ight Fade 32768 20 Pan fine LSB 21 0 65535 Tilt MSB Up down Fade 32768 22 Tilt fine LSB 23 0 255 Pan Tilt speed Fast slow Fade 0 24 0 39 40 54 55 69 70 79 80 89 90 99 100 109 110 119 120 129 130 199 2...

Страница 22: ...e holds last received data on all channels holds current scene COOLING MODE REGULATED FANS Fan speed optimized for lowest noise temperature controlled by regulating fan speed FULL Fans run at constant...

Страница 23: ...Display relative humidity in head BASE xx Display relative humidity in base TEMPERATURE MAIN PCB BASE x x C Scroll through current readings on all PCB temperature sensors main PCB pan tilt PCB CMY PC...

Страница 24: ...PAN FOCUS 127 128 127 128 Scroll through effects press ENTER to select Use UP and DOWN buttons to adjust home position Press ENTER to store LOAD DEFAULTS LOAD Load factory default calibration setting...

Страница 25: ...R 0X9078 Ballast communication error BASE FAN 1 START ERR 0X9058 Base cooling fan warning BASE FAN 1 STOP ERR 0X9059 Base cooling fan warning BASE FAN 2 START ERR 0X905A Base cooling fan warning BASE...

Страница 26: ...lled LAMP FAN1 START ERR 0X905E LAMP FAN1 STOP ERR 0X905F MAGENTA RESET FAIL 0X90A1 Magenta flag reset error PAN ENCODE ERR 0X9010 PAN RESET ERR 0X9012 PCBA CMY COLOR ERR 0X9099 PCBA EFFECT ERR 0X909B...