Installing and Configuring Your AV Equipment
N2412A/N2422A User Manual
15
NOTE:
If the LocalPlay screen does not appear, refer to the chapter Troubleshooting
on page 67
for more guidance.
NOTE:
In order for the unit to receive PoE+, it must be connected to a switch or other equipment that has a PoE+ PSE (Power
Sourcing Equipment) port. PoE+ does not pass through the daisy chain (P1) port.
CAUTION:
Do not run wiring that is connected to a PoE+ PSE port outside of the building where the PSE resides. It is for intra-building
use only.
Step 3: Connecting Encoders to the Network and Configuring Stream
Settings
1.
Using a Cat-5 cable, connect your N-Series Encoder’s
P0
port to a PoE+ enabled switch. In non-PoE applications connect a
12V regulated power supply (FGN9313) to the two-pin terminal block plug connector (labeled
+12V 3A
).
NOTE:
In order for the unit to receive PoE+, it must be connected to a switch or other equipment that has a PoE+ PSE port.
2.
In
N-Able
, select the
Unit Management
tab and click the
Auto Discover
button (if the table has not already populated itself
with the installed units). See
Figure 12
.
FIG. 12
Unit Management Page
3.
Find your Encoder in the list. N2400 units are displayed on the following tabs:
•
Unit Management
tab — N2400 units have
N2400 Encoder/Decoder
listed in their
Type
fields.
•
Video Matrix
tab — N2400 units are found on the
N2400
sub-tab (as shown in
Figure 13
).
NOTE:
If using multiple Encoders in your set up, it is important to plug in and configure one Encoder at a time. As you add Encoders
to the network, you will need to set them up to use different streams.