30
Hardware Reference Guide - NX-Series NetLinx Integrated Controllers
Wiring and Connections
The following table list the wiring specifications for the I/O ports. In this table, pin 1 is located on the right side of the port, and the
pinouts count up to the left.
IR/SERIAL Port: Connections and Wiring
The IR/SERIAL ports provide IR transmit/one-way serial connections that support high-frequency carriers up to 1.142 MHz. You
can simultaneously generate up to eight IR/Serial data signals on the NX-4200 and NX-3200, up to four on the NX-2200, and up to
two on the NX-1200.
These ports accept an IR Emitter (CC-NIRC) that mounts onto the device's IR window, or a mini-plug (CC-NSER) that connects to
the device's control jack. You can also connect a data 0 - 5 VDC device to these ports.
NX-3200 and 4200 units each ship with two CC-NIRC IR Emitters (FG10-000-11). NX-1200 and 2200 units ship with one emitter
each.
FIG. 25 displays the IR/SERIAL ports for each NX-series controller.
FIG. 25
IR/SERIAL connector (male)
NOTE:
The maximum baud rate for ports using DATA mode is 19200. Also, DATA mode works best when using a short cable length (<
10 feet).
NOTE:
For each data signal, the negative (-) terminal is for Signal GND, and the positive (+) terminal is for IR/Serial data.
The IR/Serial connector wiring specifications are listed in the following table.
I/O Port Wiring Specifications
NX-3200/4200
NX-1200/2200
Pin Signal
Function
Pin Signal
Function
1
GND
Signal GND
1
GND
Signal GND
2
I/O 1
Input/Output
2
I/O 1
Input/Output
3
I/O 2
Input/Output
3
I/O 2
Input/Output
4
I/O 3
Input/Output
4
I/O 3
Input/Output
5
I/O 4
Input/Output
5
I/O 4
Input/Output
6
12 VDC
PWR
6
12 VDC
PWR
7
GND
Signal GND
8
I/O 5
Input/Output
9
I/O 6
Input/Output
10
I/O 7
Input/Output
11
I/O 8
Input/Output
12
12 VDC
PWR
IR/SERIAL Connector Wiring Specifications (per Port)
Signal #
NX-3200/4200
Port #
NX-2200 Port # NX-1200 Port #
1
11
11
11
2
12
12
12
3
13
13
N/A
4
14
14
N/A
5
15
N/A
N/A
6
16
N/A
N/A
7
17
N/A
N/A
8
18
N/A
N/A
NX-3200/4200
NX-2200
NX-1200