6
The Advance Pellet Stove is capable of manual operation. This also allows the operator
to manually control operation during an emergency (i.e. igniter failure.) The unit can be
switched between "AUTO" and "MANUAL" at any time during operation.
NOTE: It is possible to start a fire in "Auto" and
switch to "manual" at any time. Once an ignition
cycle begins, it will continue, regardless of mode.
manual Ignition/Operation
Room Temperature Mode:
This setting will produce
a room temperature of 70 degrees with the distribution
blower at medium speed.
NOTE: during the use of this mode, if you
keep increasing the temperature dial setting to
increase the fire size, the distribution blower will
automatically come on when the ESP Temperature
reaches 350
o
F, or 81% output.
This setting will produce a large viewing fire without a
distribution blower operating.
manual Stove Temperature mode
room Temperature mode
Igniter switch to "mANuAl"
The fire will have to be lit with starting gel and a match,
or started automatically, see "Automatic Operation".
Switch to "Manual" position after the ignition cycle
begins.
The difference between "AUTO" Room Temperature
Mode and "Manual" Room Temperature Mode is that
the fire will not go out as the room temperature goes
above the control board setting. The unit can only go to
low burn and will remain there until it runs out of fuel or
until more heat is needed and the feed rate increases.
Feed rate adjustments and dial settings are the same
as "AUTO" settings.
Stove Temperature mode
Igniter switch to "mANuAl"
The advantage of this mode is to allow the operator
to have a large viewing fire without blowing extra heat
into the room.
during operation, with the temperature dial set at #3
or less, the distribution fan will not operate. A #3 on
the temperature dial and a #5 on the feed adjuster is
approximately 80% output. It is not necessary to operate
the distribution blower below this point. Therefore, there
can be a higher feed rate ( a larger viewing fire) without
an excess of hot air blowing into the room.
An example of when to use the Manual Stove
Temperature Mode is if you want to watch a large fire
and the room is already up to temperature. The Stove
Temperature Mode allows you to have a larger fire and
a lower sound level, without the distribution blower.