15
This method also provides excellent venting for normal
operation but requires the stove to be installed farther
from the wall. The vertical portion of the vent should
be three to five feet high and at least three inches from
a combustible wall. This vertical section will provide
natural draft in the event of a power failure.
This method provides excellent venting for normal
operation and allows the stove to be installed closest
to the wall. One inch from the wall is safe; however, two
or three inches allows better access to remove the rear
panel. The vertical portion of the vent should be three to
five feet high. This vertical section will provide natural
draft in the event of a power failure.
Fig.20
Fig.21
venting
KEEP COmbuSTIblES (SuCh AS
grASS, lEAvES, ETC.) AT lEAST 3
FEET AwAY FrOm ThE FluE OuTlET
ON ThE OuTSIdE OF ThE buIldINg.
CAuTION
3 ft.
to combustibles
3 ft.
to combustibles
3 ft.
to combustibles
3 ft.
to combustibles
#1 Preferred method
#2 Preferred method