Most boats have a chainplate with a single tang.
If boat has two plates forming a jaw, reverse
eye/jaw toggle so eye is down.
Important! Remove black plastic caps and
install them so crosspin will be 90 degrees
to lower clevis pin.
Crosspin
Fork
Attachment
Crosspin
Tang
Attachment
For tang-down installations,
switch plugs to this position.
Options for Snaking Stay into Foils
3
1
/
4
"
(83mm)
Eye/Jaw Reversible
1/2" (12.7 mm)
Clevis Pin
Jaw/Jaw
1
/
2
" (12.7 mm)
Clevis Pin
Make sure your toggle
looks like this!
3"
(76 mm)
Use dimensions of Harken toggle below to build stay to correct length.
Tip: Turnbuckles should be 1/2 to 2/3rds open to allow shortening for new wire stretch and for
fine-tuning mast rake.
Long Link Plate w/Toggle
*
1
/
2
" (12.7 mm) Clevis Pin)
**
5
/
8
" (15.9 mm) Clevis Pin
*2
5
/
16
" (59 mm)
**2
11
/
16
" (68 mm)
Stud/Jaw
5
/
8
" (15.9 mm)
Clevis Pin
Make sure your toggle
looks like this!
3
7
/
8
"
(98 mm)
8
7
/
8
"
(225 mm)
Thread
5
/
8
" - 18 LH
1. Swage stud at end of wire.
2. Open end of wire and install Norseman or Sta-Lok
®
stud after foil is assembled.
3. When using smaller wires, marine eye may fit. See page 12.
4. Rod adapter nosepiece for Harken rod adapter stud.
WARNING! Using a threaded nosepiece with only
adhesive at the upper rod eye terminal may result
in headstay system failure which can cause an
accident, damage to your vessel, personal injury,
or death. See www.harken.com/en/general-warn-
ings-instructions/ for additional safety information.
STA-LOK is a registered trademark of STA-LOK Terminals Ltd.
Preassembly
Toggle Deductions/Stay Into Foil Options