Chapter 5 - Block Transfers
5-9
Block Read
Command Number
7: BCD Output
Configuration
TABLE 5-10: BLOCK READ COMMAND NUMBER 7: BCD OUTPUT CONFIGURATION
Block Read
Command Number
8: Configuration of
Analog Output
BLOCK READ COMMAND NUMBER 7: BCD Output Configuration
START
WORD DEFINITIONS:
#WORDS
WORD
Command number: A value of 7 (decimal)
bit 0
1
bit 1
1
bit 2
1
bit 3
0
bit 4
0
bit 5
0
bit 6
0
bit 7
0
Format of output
bit 8
If set, will update BCD output when “print” button or remote
function is activated
bit 9
Reserved for future use
bit 10
If set, will output weight data currently displayed
bit 11
If set, will output tare value
bit 12
If set, will output net weight
bit 13
If set, will output gross weight
bit 14-15
Reserved for future use
1
0
Reserved for future use
1
1
TOTAL NUMBER OF WORDS
2
BLOCK READ COMMAND NUMBER 8: Configuration of Analog Output
START
WORD DEFINITIONS:
#WORDS
WORD
Command number: A value of 8 (decimal)
bit 0
0
bit 1
0
bit 2
0
bit 3
1
bit 4
0
bit 5
0
bit 6
0
bit 7
0
Weight parameter to be transmitted
bits 8 - 15
A value from 0 to 4 (0 = Gross, 1 = Net, 2 = Rate-of-Change,
3 = Peak Force, 4 = Totalize amount)
1
0