Block Read
Command Number
1: Full Status and
Weight Data
BLOCK READ COMMAND NUMBER 1: Full status and weight data
START
WORD DEFINITIONS:
#WORDS
WORD
Command number: A value of 1 (decimal)
bit 0
1
bit 1
0
bit 2
0
bit 3
0
bit 4
0
bit 5
0
bit 6
0
bit 7
0
Indicator Group 1 Status
bit 8
Rate-of-Change currently displayed
bit 9
Setpoint RElay #2 active
bit 10
Setpoint Relay #1 active
bit 11
Peak Force (weight) currently displayed
bit 12
Totalized weight currently displayed
bit 13
Reserved for future use
bit 14
Reserved for future use
bit 15
Reserved for future use
1
0
Indicator Group 2 Status
bit 0
Weight currently displayed in pounds units
bit 1
Zero Track feature enabled
bit 2
Reserved for future use
bit 3
Current gross weight = 0
bit 4
Weight in motion, i.e. changing
bit 5
Gross weight currently displayed
bit 6
Net weight currently displayed
bit 7
Weight currently displayed in Kilogram units
Dipswitch Settings (exterior) Status
bit 8
Re-calibrate toggle
bit 9
Option menu keypad lockout
bit 10
Setpoint menu keypad lockout
bit 11
Lb/Kg, Net/Gross, Tare, Zero keypad lockout
bit 12
Zero tracking enable
bit 13
Reserved for future use
bit 14
RS232 command lockout
bit 15
Multi-Drop enable (RS-422 only)
Note: When the HI 2151WC is configured as a blind unit, the status of the
dipswitches are not visible. See section on blind operation for more
information.
1
1
TABLE 5-2: BLOCK READ COMMAND NUMBER 1: FULL STATUS AND WEIGHT DATA