Visualization of graphic table in tabular form
The section “
Data
” lists up the values from the graph. (
Here
: Example with photovoltaic
system, solarbattery, cPµ1T13.8 und Fronius ohmpilot)
House
connection
Energy
846,9 W is drawn from the grid
Counter
7886,17 kWh was drawn in total
L1, L2, L3
current flow in the individual phases
Batterie
The charge state of the battery, charging and
discharging is shown.
Ohmpilot
The power consumption is displayed.
Only possible in combination with the
Fronius Hybrid-Series.
cPµ1 T13.8
Energy
power consumption of 5,5 W
Counter
the cPµ1 drew 2050,51 W in total
L1, L2, L3
current flow in the individual phases
EVCC
Internal data
Configuration instructions
eCB1
smartmeter
Version: 1.2.3
27