![Hardy Barth CPMICRO1 Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/hardy-barth/cpmicro1/cpmicro1_instruction-manual_3899518018.webp)
Description
Colour of core
Label
Live conductor Phase 1
BROWN
L1 (brown leakage)
Live conductor Phase 2
BLACK
L2 (black leakage)
Live conductor Phase 3
GREY
L3 (grey leakage)
Neutral
BLUE
N (blue leakage)
Protective conductor
GREEN-YELLOW
GREEN-YELLOW LEAKAGE
DANGER!
The previously named colour codes are NOT obligatory on an international
level: If the cores are colour-coded differently please contact a qualified
electrical company and have them examine the lead and if required, replace
it.
4. Plug the LED-Display back in and re-attach the cover of the charging station before
securing it with its screws.
5. Reactivate the circuit breakers and all fault-current-circuit-breakers.
The electrical installation is now complete.
PLEASE NOTE!
The first time operating the charging station should be executed by a
qualified electrician in any case. They can determine correct operation as
well as repair malfunctions or mistakes that had been made during the
installation.
Instruction Manual
cPμ1
charging station
Version: 1.3.3
18