CUS-013-0028-09
Weekly Inspection
Thoroughly inspect the venting components / chimneys supplied with the rotisserie for signs of damage
(dents, perforations, etc.). Replace with certified Hardt components if required. Ensure that the electrical cord,
water and gas lines are free from damage and kinks.
Flame Shields
It is important that the flame shields on the back wall
remain secured in place for optimal performance. At
different intervals, it is good practice to ensure that they
are properly in place by referring to the illustrations on
this page. In the event that they need to be removed
(i.e. to have access to the back burner), do the following:
1. Starting with the
right
flame shield, lift it out of its
upper slot
(A)
, side wall tab
(B)
and
floor stopper
(C)
.
Carefully remove it out of the oven cavity.
Figure 5-6
2. Lift the
left
flame shield out of its side wall tab
(B)
and floor stopper
(C)
.
Carefully remove it out of the oven cavity.
Figure 5-7
3. Reinstall the flame shields in reverse order
install left shield first, followed by the right shield.
Ensure all tabs are correctly inserted into their
corresponding slots and ensure that the shields
are positioned behind the floor stopper.