
8 - Technical specifications
111
Electrical connections
Electrical connections for SPRAY II
39- or 37-poled plug with cable.
39-pole
37-pole
SPRAY II
1a
5
S1+
1b
6
S1-
1c
26
End nozzle L
2a
7
S2+
2b
8
S2-
2c
25
End nozzle R
3a
9
S3+
3b
10
S3-
3c
29
+12V sensor
4a
11
S4+
4b
12
34-
4c
4
PWM 1TX
5a
14
S5+
5b
15
S5-
5c
27
GND
6a
16
S6+
6b
17
S6-
6c
13
Optional 5 Reg. feedback
7a
18
S7+
7b
19
S7-
7c
33
Option 1 4-20mA
8a
37
S8+
8b
36
S8-
8c
32
Option 2 Frq
9a
35
S9+/Air angle 0-5V
9b
34
S9-/Fan speed 0-5V
9c
not connected
Option 3/Tank gauge
10a
21
On/off+
10b
22
On/off-
10c
not connected
PWM Output option
11a
23
P
11b
24
Pressure-
11c
28
Flow
12a
20
Foam blop 0-5V
12b
1
Option 4 Rx
12c
31
Speed
13a
3
FM L
13b
2
FM R
13c
30
Gnd sensor
Содержание NAVIGATOR DELTA
Страница 4: ...1 EC Declaration 4 ...
Страница 10: ...Table of Contents 10 ...
Страница 14: ...2 Safety notes 14 ...
Страница 32: ...3 Description 32 ...
Страница 54: ...4 Sprayer setup 54 ...
Страница 74: ...5 Operation 74 ...
Страница 76: ...6 Maintenance 76 Boom lubrication oiling plan ...
Страница 77: ...6 Maintenance 77 Trailer lubrication oiling plan P T O lubrication oiling plan Serie 100 type P T O shaft C 50 ...
Страница 104: ...7 Fault finding 104 ...
Страница 120: ...HARDI INTERNATIONAL A S Herthadalvej 10 DK 4840 Nørre Alslev DENMARK ...