6 - Maintenance
140
Nozzle Holder Assembly
If leaks of fluid occur in the nozzle holders on the spray boom, it is necessary to check the gaskets. The nozzle holder need
to be disassembled to locate the gaskets. Occasional maintenance of the gaskets and nozzle holders is recommended.
Poor sealings are usually caused by:
•
Missing O-rings
•
Damaged or incorrectly seated O-rings
•
Dry or deformed O-rings
•
Foreign objects.
In Case of Leaks
1.
Disassemble the pipe fitting.
2.
Check condition and position of O-ring. Replace it if damaged or cracked.
3.
Clean and lubricate the O-ring. Lubricate all the way around using a non-mineral lubricant.
4.
Reassemble the O-ring or gasket and pipe fittings. When tightening the fittings, a little mechanical leverage may be
used.
How To Disassemble Nozzle Holders
Nozzle holder assembled and mounted on the spray boom.
The black plastic parts are snapped together.
To disassemble, insert a slotted screwdriver (B) and press, until the
locking piece (A) snaps out.
Содержание MEGA VPZ MASTER
Страница 1: ...MEGA VPZ Original Instruction book 67050600 110 version 1 10 GB 03 2018 www hardi international com...
Страница 4: ...1 EU Declaration 4...
Страница 10: ...Table of Contents 10...
Страница 42: ...2 Safety Notes 42...
Страница 68: ...3 Description 68...
Страница 118: ...5 Operation 118...
Страница 121: ...6 Maintenance 121 Lubrication Plan Boom Centre Close up of Glide Shoes to be Lubricated...
Страница 122: ...6 Maintenance 122 Lubrication Plan Boom Wings Both boom wings left and right are to be lubricated equally 10...
Страница 172: ...8 Technical Specifications 172...
Страница 176: ...Index 176...
Страница 178: ...HARDI INTERNATIONAL A S Herthadalvej 10 DK 4840 N rre Alslev DENMARK...