4 - System setup
23
Daily settings
System start-up
When the HC 5500 is turned on a boot sequence is started while the
controller is initiating it self. If the Controller is put into operation for the
very first time it will prompt for date and time, [Set clock to enable
register]. Please see “Menu 2.4 Set clock” for details on setting of clock.
During start-up it shows information about itself in the following order:
1.
A screen showing that the controller is a HC 5500 and a software
version in 3rd line of display. In 4th line of display a serial number
for the specific controller is shown.
2.
A screen showing boom length in 3rd line of the display. Number
of sections programmed into the controller are shown in the 4th
line. These datas should reflect the sprayer it is mounted to - if not,
please contact your local HARDI dealer to correct this.
3.
If the sprayer is equipped with LookAhead and this is enabled in
the HC 5500 it will promt user for a nozzle choice - see section
“LookAhead nozzle choice”. If no LookAhead is available this screen
will not appear and HC 5500 will be ready for use.
4.
To prevent unintended Track movements the track selection
switch on the hydraulic control box must be set to “auto”, if the HC
5500 is switched on while the boom is unfolded and/or the sprayer
is steered out. The display then tells that “auto” is on. If “auto” has
not been selected, the controller will promt you to select “auto” on.
Press
to confirm this and then the controller is ready to use.
LookAhead nozzle choice
If LookAhead or pressure based regulation is enabled the HC 5500 it will
promt user for a nozzle choice at every start-up of the controller. Display
will show last used nozzle by displaying its colour and ISO code in the
display.
If the nozzle used at last spray job is going to be re-used, then press
.
Selecting another nozzle:
1.
Select another nozzle by pressing
or
.
2.
Confirm the choice by pressing
.
3.
If a selected nozzle holds no LookAhead calibration in the HC 5500
memory then it should be calibrated - see section “Menu 3.7
LookAhead” in the chapter “Menu 3 Calibration”.
Custom nozzle flow rate is also defined in “Menu 3.7.X LookAhead
calibration”.
HC 5500
SW X.XX
S/N XXXXXXXX
BOOM:
XX.X m
SECTIONS:
X
TRACK: AUTO
Press ENTER
SELECT NOZZLE
yyyyyyyyyyyyyyyy
ISO XXXX
CALIBRATE!
yyyyyyyyyyyyyyyy
ISO XXXX
Содержание HC5500
Страница 6: ...Table of Contents 6 ...
Страница 8: ...1 CE Declaration 8 ...
Страница 10: ...2 Safety notes 10 ...
Страница 26: ...4 System setup 26 ...
Страница 30: ...5 Menu 1 Daily settings 30 ...
Страница 60: ...8 Menu 4 Toolbox 60 ...
Страница 66: ...11 Maintenance 66 ...
Страница 76: ...14 Technical specifications 76 ...
Страница 78: ...Index 78 ...
Страница 80: ...HARDI INTERNATIONAL A S Helgeshøj Allé 38 DK 2630 Taastrup DENMARK ...