Page 25
For technical questions, please call 1-888-866-5797.
Item 56825
S
AFET
y
M
AINTENAN
c
E
B
ASI
c W
EL
d
IN
g
W
EL
d
IN
g T
Ip
S
SETUP
problem
possible causes
Likely Solutions
Weak Arc Strength
1. Incorrect line voltage.
2. Improper gauge or length of cord.
1. Check the line voltage and, if insufficient, have
a licensed electrician remedy the situation.
2. Do not use an extension cord on this Welder.
Use only one of the supplied power cords for
this Welder or an identical replacement cord.
Welding Arc
Not Stable.
1. Loose electrode cable
or ground cable.
2. Damaged electrode holder or loose
connection within electrode holder.
3. Adjust current setting.
4. Shielding gas getting low.
1. Check to ensure that all connections are tight.
2. Have a qualified technician inspect and
repair/replace as necessary.
3. Make sure setting matches
recommended setting on chart.
4. Replace shielding gas cylinder.
Follow all Safety precautions whenever diagnosing or servicing the tool.
disconnect power supply before service.
Fault code Table
code
problem
possible causes
Likely Solutions
F01
Overheated
The duty cycle limit of the
machine has been exceeded.
Allow the machine to cool down. Keep the machine
plugged in and turned on to allow the fan to continue to
run. Reduce duration or frequency of welding periods.
Refer to Duty Cycle (Duration of Use) on page 15.
Check for any obstructions blocking air flow into the
machine and ensure proper clearance between any
obstacles and the vents on all sides of the machine.
F02
Incorrect Input
Voltage
The input voltage is too
high or too low.
Verify the voltage at the outlet and
the connection to the outlet.
F05
Torch Triggers
Before Machine
Is Turned On
The TIG torch trigger is
stuck or is triggered when
turning on the machine.
Turn OFF the machine and ensure
the TIG torch trigger is reset.
F09
Output Short
Circuited
Ground clamp and TIG torch or
electrode holder are in contact.
Check the connection of the ground clamp and TIG
torch or electrode holder to make sure they are not in
contact. Lift the electrode holder or TIG torch up to take
the electrode away from the workpiece and restart arc.