manualshive.com logo in svg
background image

Page 12

For technical questions, please call 1-888-866-5797.

Item 62508

Limited 90 Day Warranty

Harbor Freight Tools Co. makes every effort to assure that its products meet high quality and durability standards, 

and warrants to the original purchaser that this product is free from defects in materials and workmanship for the 

period of 90 days from the date of purchase. This warranty does not apply to damage due directly or indirectly, 

to misuse, abuse, negligence or accidents, repairs or alterations outside our facilities, criminal activity, improper 

installation, normal wear and tear, or to lack of maintenance. We shall in no event be liable for death, injuries 

to persons or property, or for incidental, contingent, special or consequential damages arising from the use of 

our product. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the 

above limitation of exclusion may not apply to you. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER 

WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS.
To take advantage of this warranty, the product or part must be returned to us with transportation charges 

prepaid. Proof of purchase date and an explanation of the complaint must accompany the merchandise. 

If our inspection verifies the defect, we will either repair or replace the product at our election or we may 

elect to refund the purchase price if we cannot readily and quickly provide you with a replacement. We will 

return repaired products at our expense, but if we determine there is no defect, or that the defect resulted 

from causes not within the scope of our warranty, then you must bear the cost of returning the product.
This warranty gives you specific legal rights and you may also have other rights which vary from state to state.

3491 Mission Oaks Blvd.  •  PO Box 6009  •  Camarillo, CA 93011  •  1-888-866-5797

PLEASE READ THE FOLLOWING CAREFULLY

THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS DIAGRAM IN THIS MANUAL 

AS A REFERENCE TOOL ONLY.  NEITHER THE MANUFACTURER NOR DISTRIBUTOR MAKES ANY 

REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO MAKE 

ANY REPAIRS TO THE PRODUCT OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE 

PRODUCT.  IN FACT, THE MANUFACTURER AND/OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS 

AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS AND 

NOT BY THE BUYER. THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS 

TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO, OR ARISING OUT OF HIS OR HER 

INSTALLATION OF REPLACEMENT PARTS THERETO.

Содержание PacificHydroStar

Страница 1: ...e may not be included When unpacking make sure that the product is intact and undamaged If any parts are missing or broken please call 1 888 866 5797 as soon as possible Save This Manual Keep this manual for the safety warnings and precautions assembly operating inspection maintenance and cleaning procedures Write the product s serial number in the back of the manual near the assembly diagram or m...

Страница 2: ...and or di 2 ethylhexyl phthalate DEHP chemicals known to the State of California to cause cancer and birth defects or other reproductive harm Wash hands after handling California Health Safety Code 25249 5 et seq 11 WARNING This product contains lead a chemical known to the State of California to cause cancer and birth defects or other reproductive harm California Health Safety Code 25249 5 et seq...

Страница 3: ...ecifications Electrical Rating 120VAC 60Hz 5A Inlet Outlet Diameter 1 NPT Maximum Pressure 50 PSI Maximum Flow 550 GPH Maximum Suction Lift 23 Maximum Delivery Height 110 Maximum Water Temperature 95 F 35 C Maximum Ambient Temperature 104 F 40 C Power Cord Length 6 3065430 ...

Страница 4: ...Page 4 For technical questions please call 1 888 866 5797 Item 62508 Functions Inlet Outlet Priming Plug Power Cord not shown Figure A ...

Страница 5: ...nresidential facility providing water for human consumption that is not lead free Power Supply 1 The pump is equipped with a shock proof plug according to regulations The pump is designed to be connected to 120 VAC 60 Hz safety socket 2 Make sure that the socket is sufficiently secured and is in excellent condition 3 When the plug is inserted into the socket the pump will be on standby WARNING If ...

Страница 6: ...ncluded to help keep Pump primed 3 Remove strainer from Check Valve by turning it counterclockwise Figure B 4 Incorporate the following items into the plumbing See Figure D a check valve on inlet make sure it is positioned so water will flow in the proper direction Figure C b in line shutoff ball valves sold separately on inlet and outlet and c unions sold separately on inlet and outlet 5 Remove P...

Страница 7: ...o the water supply with a 120V GFCI protected outlet nearby Note The Pump is not self priming A Check Valve is included to help keep Pump primed Figure E 2 Attach hoses to Inlet and Outlet 3 Attach Check Valve to Inlet hose 4 Place Inlet hose in water source 5 Remove Priming Plug fill cavity with water until water overflows Replace Priming Plug and tighten securely Inlet Hose Outlet Hose Inlet Out...

Страница 8: ...socket is in good condition 5 Verify that water and moisture cannot get near the power supply socket 6 Verify that the pump is installed so as to prevent running dry General Operation 1 BEFORE EVERY USE make sure Impeller can move freely by inserting slotted screwdriver into center hole on Fan Cover and turning fan Figure G Fan Cover 2 Dry hands then plug Power Cord into a 120V GFCI protected outl...

Страница 9: ...ng 1 Pump overheated 2 Fuse is blown or circuit breaker tripped 3 Voltage is too low 1 Wait for Pump to cool off restart pump MAKE SURE YOU DO NOT HAVE A DRIPPING FAUCET OR SLOW LEAK this will cause the pump to run continuously and overheat 2 Disconnect power and replace fuse or reset circuit breaker 3 Check voltage being supplied to pump Motor runs but no water is being delivered 1 Pipes are froz...

Страница 10: ...loth 3 WHEN TAKING OUT OF SERVICE a Dry hands then unplug Pump b Close Inlet and Outlet Valves 4 TO PREVENT DAMAGE TO THE PUMP a If there is a possibility that it will be exposed to freezing temperatures Take out of service according to 3 above Disconnect pipes from pump Tip Pump to drain water b Do not expose the pump to freezing temperatures for an extended period Temporary Installation 1 BEFORE...

Страница 11: ...r 1 15 Ball Bearing 2 16 Wave Spring 1 17 Fan Cover 1 18 Fan 1 19 Bolt M5 x 18 2 Item Description Qty 20 End Plate 1 21 Mechanical Bolt 2 22 Cord Clip 1 23 Gasket 1 24 Cord Clip 1 25 Wave Spring 1 26 Mechanical Bolt 1 27 Screw Cap 1 28 Seal Washer 1 29 Sealed Sheath 1 30 Cable 1 31 Mechanical Bolt 4 32 Capacitor Box 1 33 Sealing Ring 1 34 Cord Clip 3 35 Capacitor 1 36 Stator 1 37 Priming Plug 1 38...

Страница 12: ...tion of the complaint must accompany the merchandise If our inspection verifies the defect we will either repair or replace the product at our election or we may elect to refund the purchase price if we cannot readily and quickly provide you with a replacement We will return repaired products at our expense but if we determine there is no defect or that the defect resulted from causes not within t...

Отзывы: