read the EnTirE iMpOrTanT SaFETy inFOrMaTiOn section at the beginning of this manual
including all text under subheadings therein before set up or use of this product.
TO prEVEnT SEriOuS inJury anD FirE: Operate only with proper spark arrestor installed.
Operation of this equipment may create sparks that can start fires around dry vegetation.
a spark arrestor may be required.
The operator should contact local fire agencies for laws or regulations relating to fire
prevention requirements.
At high altitudes, the engine’s carburetor, governor, and any other parts that control the fuel-air ratio
will need to be adjusted by a qualified mechanic to allow efficient high-altitude use and
to prevent damage to the engine and any other devices used with this product.
Grounding
1. The Generator must be properly grounded
in accordance with all relevant electrical
codes and standards before operation.
Have the unit grounded by a qualified electrician
if you are not qualified to do so.
2. To ground the Generator, connect a #4 AWG
grounding wire (not included) from the Grounding
Terminal on the Control Panel to a grounding rod
(not included). The grounding rod must be an
earth-driven copper or brass rod (electrode)
which can adequately ground the Generator.
3. Refer to local regulations for
ground source information.
Electric Starter Battery Connection
For the electric start function, the included 12 VDC
Battery must be connected before first use.
1. Remove the Battery Access Panel.
2. Make sure the black strap stretches over the top of
the Battery and hooks into the Battery Platform.
3. Remove the covers from the Battery Terminals.
4. Locate the black and red battery cables.
5. Connect the red cable to the positive battery
terminal first. Then connect the black
cable to the negative battery terminal.
6. Replace the Battery Access Panel.
Components and Controls
OFF
OFF
Engine
Switch
Economy
(ESC) Switch Voltage
Selector
CO alarm
Light
Output
Overload
Low Oil
Combination
Switch
12VDC receptacle
12VDC Breaker
reset Button
Ground
Terminal
120VaC 30a 120VaC
20a GFCi
120/240VaC
30a
Circuit
Breaker
120VaC
Breaker resets
parallel Kit
Terminals
Hour Meter
5V uSB-a
Figure a: Control panel