ASSEMBLY INSTRUCTIONS

5b. Connect BARE/GREEN ground wire from outlet 

box to BARE ground wire from fixture (A) with 
wire connector (AA). Connect WHITE wire from 
fixture (A) to WHITE wire from outlet box using 
existing wire connector or wire connector (AA). 
Connect BLACK wire from fixture (A) to BLACK 
wire from outlet box using existing wire connector 
or wire connector (AA).

NOTE:

 Screw wire connectors (AA) on in a 

clockwise direction.

      

WARNING:

 Never connect ground wire to 

WHITE or BLACK power supply wires.

      WARNING: 

To reduce the risk of fire, 

electrical shock or personal injury, wire 
connectors (AA) are designed to accept only one 
12-gauge house wire and two lead wires from the 
light fixture. If your house wire is larger than 
12-gauge or there is more than one house wire to 
connect to the corresponding fixture lead wires, 
consult an electrician for the proper size wire 
connectors to use.

Hardware Used

Wire Connector

  x 3

AA

5b

Outlet

Box

A

6. Wrap electrical tape (not included) around each 

individual wire connector (AA) down to the wire. 

       

WARNING:

 Make sure no bare wire or wire 

strands are visible after making connections.

Push wire connectors (AA) gently back into outlet 
box. Carefully push excess wiring into outlet box. 

AA

AA

6

Outlet

Box

A

AA

AA

AA

BARE/GREEN

BLACK

WHITE

AA

Содержание WL137MW

Страница 1: ...ment at 1 888 251 1003 8 a m 8 p m EST Monday Sunday You could also contact us at partsplus lowes com or visit www lowespartsplus com ITEM 4145468 MODEL WL137MW ATTACH YOUR RECEIPT HERE ADJUNTE SU REC...

Страница 2: ...y Information 3 Preparation 4 Assembly Instructions 5 Care and Maintenance 9 Troubleshooting 9 Warranty 9 TABLE OF CONTENTS B C A A Fixture 1 B Mounting Plate 1 preassembled to fixture A C Mounting Pl...

Страница 3: ...subject to electrical shock which could cause serious injury or death DO NOT connect the bare or green insulation fixture ground wire to the black HOT current carrying wire or the white NEUTRAL house...

Страница 4: ...malfunction install fixture at least 4 ft above the ground floor SAFETY INFORMATION WARNING TURN OFF ELECTRICITY at main fuse box or circuit breaker box before beginning installation by removing the...

Страница 5: ...ilure to disconnect power supply prior to installation may result in serious injury or death 1 1 Remove existing fixture and disconnect all electrical wiring 2 2 Outlet Box 3 3 A B C C Remove mounting...

Страница 6: ...ears on mounting plate B are level horizontally This will help ensure the fixture A is level when attached Tighten machine screws BB completely to secure mounting plate B CAUTION The fixture must be m...

Страница 7: ...lectrical shock or personal injury wire connectors AA are designed to accept only one 12 gauge house wire and two lead wires from the light fixture If your house wire is larger than 12 gauge or there...

Страница 8: ...use level to check fixture A adjust if necessary 7 A C Restore power and test fixture A If light does not function please refer to TROUBLESHOOTING on the following page 9 B C 8 Install one 60 watt max...

Страница 9: ...ver fixtures becoming defective due to misuse accidental damage or improper handling and or installation and specifically excludes liability for direct incidental or consequential damages improper pac...

Страница 10: ...s reservados Preguntas problemas piezas faltantes Antes de volver a la tienda llame a nuestro Departamento de Servicio al Cliente al 1 888 251 1003 de lunes a domingo de 8 a m a 8 p m hora est ndar de...

Страница 11: ...e seguridad 12 Preparaci n 13 Instrucciones de ensamblaje 14 Cuidado y mantenimiento 18 Soluci n de problemas 18 Garant a 18 B C A A L mpara 1 B Placa de montaje 1 preensamblada a la l mpara A C Torni...

Страница 12: ...l mpara al conductor negro DE CORRIENTE que lleva la corriente o al conductor blanco NEUTRO de la casa Conectar el conductor de tierra desnudo o verde de la l mpara al conductor negro o blanco de la...

Страница 13: ...un cable en la casa para conectar los cables conductores de la l mpara correspondientes preg ntele a un electricista cu l es el tama o adecuado de los conectores de cables que debe utilizar Para reduc...

Страница 14: ...l suministro de electricidad antes de la instalaci n pueden producirse lesiones graves o la muerte 1 Retire la l mpara existente y desconecte el cableado el ctrico 2 1 2 Caja de salida ON OFF ON OFF 3...

Страница 15: ...das horizontalmente Esto ayudar a garantizar que la l mpara A est nivelada al fijarla Apriete los tornillos para metal BB para fijar la placa de montaje B PRECAUCI N la l mpara se debe montar en una c...

Страница 16: ...incendios descargas el ctricas o lesiones personales los conectores de cables AA incluidos con esta l mpara est n dise ados para soportar solo un cable de la casa de calibre 12 y dos cables conductor...

Страница 17: ...a de montaje C examine la l mpara A con un nivel y aj stela si es necesario 7 A C 9 B C 8 Instale una bombilla incandescente de base est ndar de 60 vatios como m ximo no se incluye o una bombilla CFL...

Страница 18: ...e espec ficamente toda responsabilidad por da os directos accidentales o resultantes embalaje incorrecto de productos devueltos y da os por fuerza mayor Debido a que algunos estados no permiten exclus...

Отзывы: