background image

IG Series 

LED Parking Luminaire

Junction Box and Pendant Mount 

INSTALLATION INSTRUCTIONS

1 of 2

LPN00305X0001A0_A

TO INSTALL:

1

4

2

IMPORTANT SAFEGUARDS

When using electrical equipment, basic safety precautions should always be followed 

including the following:

READ AND FOLLOW ALL SAFETY INSTRUCTIONS

1.  DANGER

- Risk of shock- Disconnect power before installation.

DANGER

 – Risque de choc – Couper l’alimentation avant l’installation.

2.  This luminaire must be installed in accordance with the NEC or your local 

electrical code. If you are not familiar with these codes and requirements, consult 

a qualified electrician. 

Ce produit doit être installé conformément à NEC ou votre code électrique local. 

Si vous n’êtes pas familier avec ces codes et ces exigences, veuillez contacter un 

électricien qualifié. 

3.  DO NOT lift luminaire by the power leads.

4.  DO NOT carry or lift luminaire by wireform. Wireform is only for supporting luminaire while 

making wiring connections.

SAVE THESE INSTRUCTIONS FOR FUTURE 

REFERENCE

JUNCTION BOX MOUNTING

STEP 1:

Attach mounting plate to customer 
supplied junction box with the clips on the 
Mounting Plate directed parallel to vehicle 
traffic as shown in Figure 2. Torque to  
20 in-lbs. See 

Figure 1 and 2.

STEP 2:

For hands-free wiring locate the wireform 
on luminaire and attach it to the clip on 
the Mounting Plate. See 

Figure 3.

STEP 3:

Make wiring connections per 

“Electrical 

Connections”

 section.

STEP 4:

After wiring connections have been made, 
tuck all wires into junction box ensuring 
that no wires are pinched. Remove 
wireform on luminaire from the clip on the 
mounting plate. Fold the wireform back 
down onto the luminaire.

STEP 5:

Attach luminaire to the Mounting Plate 
by pressing up on the luminaire until the 
slots on the luminaire engage with the 
clips on the Mounting Plate and rotate 
until clips lock securely. To secure install 
a minimum of (2) supplied screws across 
from each other into the mounting plate 
clips on the underside of the luminaire. 
See 

Figure 4. 

NOTE:

 May require extra pressure on 

luminaire to engage clips into slots. Only 
apply pressure on housing body NOT on 
the luminaire lens.

NOTE:

 If the mounting plate clips 

become deformed during installation, 
slightly reopen the clips back up using a 
screwdriver to ensure proper install of 
luminaire.

(4) Luminaire Slots

(4) Clips

Mounting 

Plate

Mounting Plate

Wireform

Mounting 

Plate Clip

View of Underneath 

Luminaire

(4) Mounting 

Plate Clips

Luminaire 

Slots

(2) Screws

Mounting Plate

3

Wireform

Clips

Mounting Plate

NOTE:

•  During installation and maintenance handle 

the luminaire only by the housing NOT by the 
lens.

Отзывы: