STEP 6:

Lightly pull on the luminaire to verify 
luminaire is securely mounted.

FIXTURE SERVICING AND 

MAINTENANCE

STEP 1:

If supply wiring splices need to be inspected 
or if luminaire needs to be removed, fully 
loosen the (2) screws and rotate luminaire to 
disengage from Mounting Plate. 

STEP 2:

To re-install luminaire, when finished with 
servicing or maintenance follow Step 2-6 in 
“Junction Box Mounting” section above.

PENDANT MOUNTING (OPTIONAL)

STEP 1:

Attach Pendant Mount Plate to customer 
supplied pendant kit. 

NOTE:

 Not recommended for use with a 

hang straight pendant. Cree does not provide 
a counterbalance system.

STEP 2:

Feed customer supplied leads through 
customer supplied pendant kit and the  
Pendant Mount Plate. See 

Figure 5.

STEP 3:

For hands-free wiring locate the wireform 
on luminaire and attach it to the clip on the  
Pendant Mounting Plate. See 

Figure 5.

STEP 4:

Make wiring connections per 

“Electrical 

Connections”

 section. Once wire 

connections have been made remove 
wireform on luminaire from the clip on the 
mounting plate. Fold the wireform back 
down onto the luminaire.

STEP 3:

Attach luminaire to the Pendant Mounting 
Plate by pressing up on the luminaire until 
the slots on the luminaire engage with the 
clips on the Pendant Mounting Plate and 
rotate until clips lock securely. To secure 
install a minimum of (2) supplied screws 
across from each other into the pendant 
mounting plate clips on the underside of the 
luminaire. See 

Figure 5. 

NOTE:

 May require extra pressure on 

luminaire to engage clips into slots. Only 
apply pressure on housing body NOT on the 
luminaire lens.

NOTE:

 If the pendant mounting plate clips 

become deformed during installation, 
slightly reopen the clips back up using a 
screwdriver to ensure proper install of 
luminaire.

LED LUMINAIRE MAINTENANCE

CLEANING INSTRUCTIONS:

Regular cleaning of the light LED luminaire 
is required to keep the LED luminaire 
operating optimal optical performance.
•  Cleaning intervals to be no more than 

twelve months for IESNA Clean category 
environments and more frequently for 
dirtier conditions.

•  Care should be taken as to not damage 

the lens and/or the interior reflective 
surface as these components are critical 
for optimal performance.

•  Do not use any type of cleaners or stiff 

brushes on the LED luminaire. Use 
water with mild detergent and soft cloth.

ELECTRICAL CONNECTIONS

STEP 1:

Make the following Electrical Connections for products rated 120V, 277V, 
or 347V (Line-Neutral), or rated 208V, or 240V (Line-Line):

a.  For products rated 120V, 277V or 347V, connect the Black lead 

from the luminaire to the LINE supply wiring inside the junction 
box or for products rated 208V, or 240V, connect to the HOT 1 
supply wiring.

b.  For products rated 120V, 277V or 347V, connect the White lead 

from the luminaire to the NEUTRAL supply wiring inside the 
junction box or for products rated 208V, or 240V, connect to the 
HOT 2 supply wiring.

c.  Connect the Green or Green/Yellow lead from the luminaire to the 

GROUND supply wiring inside the junction box.

   LINE
OR HOT 1

GROUND

LINE-BLACK

GROUND-GREEN

NEUTRAL-WHITE

NEUTRAL
OR HOT 2

SUPPL

Y WIRING

LUMINAIRE

JUNCTION

BOX

5

View of Underneath 

Luminaire

(4) Pendant 

Mounting 

Plate Clips

Luminaire 

Slots

(2) Screws

(4) Luminaire Slots

(4) Clips

Pendant 

Mounting Plate

Wireform