PROBLEM
POSSIBLE CAUSE
CORRECTIVE ACTION
Fan does not move.
1. Power is off or fuse is blown.
2. Faulty wire connection.
3. Learning code process between fan
and remote control transmitter may
not have been successful and
learning code was not activated.
1. Turn power on or check fuse.
2. Turn power off. Loosen canopy
and check all connections.
3. Turn off power and repeat
instructions in Step 2 on page
15.
Noisy operation.
1. Blades are loose.
2. Fan is new.
1. Tighten all blade screws.
2. Allow fan a “break in” period of
a few days, especially when
running the fan at Medium and
High speeds.
Excessive wobbling.
1. Blades are loose.
2. Unbalanced blades.
3. Fan not securely mounted.
4. Fan too close to vaulted ceiling.
5. Set screw(s) on motor housing yoke
is (are) not tightened properly.
1. Tighten all blade screws.
2. Switch one blade with a blade
from the opposite side.
3. Turn power off. Carefully loosen
canopy and verify mounting
bracket is secure.
4. Move fan to another location.
5. Tighten yoke set screw(s)
securely.
NOTE:
A small amount of "wobble" is normal and should not be considered a defect.
TROUBLESHOOTING
Fan operates but
light fails.
1. Wires in canopy not wired
properly.
2. Wall switch to fan is off.
1. Check wires in canopy and, if
necessary, re-wire according to
instructions on page 11 and
page 13, step 3.
2. Make sure wall switch to
fan is on.