18
Lowes.com/harborbreeze
CARE AND MAINTENANCE
At least twice each year, lower the canopy to check the downrod assembly, and then tighten all
screws on the fan . Clean the motor housing with only a soft brush or lint-free cloth to avoid scratching
the finish. Clean the blades with a lint-free cloth.
Bulb Replacement: Use 40-watt max . candelabra-base incandescent or CFL equivalent .
Battery Replacement: Use a 23-amp, 12-volt alkaline battery .
Important:
Shut off the main power supply before you begin any maintenance tasks . Do not use
water or a damp cloth to clean the ceiling fan .
TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
CORRECTIVE ACTION
The fan does not
move .
1 . The power is off or the fuse is
blown .
2 . There is a faulty wire connection .
3 . The single-pin connectors are not
connected properly .
4 . The DC motor is obstructed
during operation .
5 . The power of the motor is over
80W .
1 . Turn the power on or check the
fuse .
2 . Turn the power off . Loosen
the canopy and check all
connections .
3 . Check that the single-pin
connectors from the light kit and
fan are connected properly .
4 . Disable the power supply to the
fan motor and re-start the motor .
5 . The blade is overweight . Do not
install the unapproved blades .
The fan is noisy .
1 . The blades are loose .
2 . There is a cracked blade .
3 . The wall control is not compatible
with the fan .
4 . The outlet box is not secure .
5 . The mounting bracket is not
secure .
1 . Check and tighten all screws
that hold the fan blades to the
blade arms and the motor .
2 . Replace the cracked blade .
3 . Do not use a full range dimmer
switch to control the fan speed .
4 . Ensure the outlet box is secured
to the building structure .
5 . Ensure the mounting bracket is
secured to the outlet box and
that the screws are tight .